<ArrayList><item><subject>&lt;![CDATA[JEOL 500MHz NMR]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="VARIAN UNITY INOVA 500NMR" src="/ord/en/app/machine/image?module=corefacilities&amp;amp;detailNo=1167399863227256832&amp;amp;init=N" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li>&lt;strong>NMR500&lt;/strong>&lt;br />&#xd;
	Brand Model: JEOL ECZ500R/S1&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Prof.&amp;nbsp;Liu, Hsueh-Ju&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 56547&lt;/li>&#xd;
	&lt;li>&lt;strong>Equipment management personnel: Dr.&amp;nbsp;Cheng, You-Song&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 31510&lt;br />&#xd;
	Email &lt;a href="mailto:gnoosuy@nycu.edu.tw" title="gnoosuy@nycu.edu.tw">gnoosuy@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument location: Room 102B, Science Hall 2,&amp;nbsp;Guanfu Campus&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-05-21</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="content">&lt;strong>Instrument introduction&lt;/strong>&lt;br />&#xd;
This instrument is a liquid nuclear magnetic resonance spectrometer equipped with a superconducting magnet with a magnetic field of 11.74 Tesla (500 MHz).&lt;br />&#xd;
It is a liquid double resonance system. The high frequency of the probe can be switched between single tune or dual tune, and can execute 1H{19F}, 19F{1H} and X{1H, 19F}.&lt;br />&#xd;
In addition to 13C for low frequency, the measurable range is 31P~15N, 39K, 109Ag.&lt;br />&#xd;
It can be used with various experiments of temperature change detection.&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Instrument brand, model, purchase period&lt;/strong>&lt;br />&#xd;
Brand: Japan JEOL&lt;br />&#xd;
Model: ECZ500R/S1&lt;br />&#xd;
Purchase period: 2021.12&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Important Specifications&lt;/strong>&#xd;
&lt;ol>&#xd;
	&lt;li>Magnetic field: 11.74 Tesla (the hydrogen nucleus resonance frequency is 500MHz)&lt;/li>&#xd;
	&lt;li>Probe: 5mm HFX probe&lt;/li>&#xd;
	&lt;li>High and low temperature variable temperature system device: the allowable temperature range is -100~+150℃&lt;/li>&#xd;
	&lt;li>64 slots auto sample changer&lt;/li>&#xd;
	&lt;li>Delta NMR data processing software&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div></page1><page2Title>service items</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="content">&lt;strong>How to apply:&lt;/strong>&lt;br />&#xd;
Please refer to the National Science and Technology Council/Valuable instrument information system, log in with your user account and password to make an appointment.&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>service items:&lt;/strong>&lt;br />&#xd;
Sample preparation instructions: After the sample to be tested is completely dissolved in a suitable deuterated solvent (D-solvent), it is placed in a special 5mm NMR tube with a height of 4-5 cm.&#xd;
&lt;ul>&#xd;
	&lt;li>One-dimensional homonuclear experiments: 1H, 1D-NOE, homo-decouple.&lt;/li>&#xd;
	&lt;li>One-dimensional heteronuclear experiments: 31P~15N, 39K, 109Ag (13C), etc. perform decouple experiments on 1H, 19F.&lt;/li>&#xd;
	&lt;li>2D experiments: COSY, NOESY, ROESY, HSQC, HMBC, TOCSY, etc.&lt;/li>&#xd;
	&lt;li>Other experiments: DOSY, 1H-19F HOESY, kinetic experiments&lt;/li>&#xd;
	&lt;li>Variable temperature experiment: constant temperature or variable temperature experiment in the temperature range of -100~+150℃&lt;/li&gt;&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div></page2><page3Title>System open level</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="content">&lt;strong>System open level&lt;/strong>&#xd;
&lt;ol>&#xd;
	&lt;li>General working hours: (to be determined)&lt;/li>&#xd;
	&lt;li>Night and Holiday Periods: (To be confirmed)&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;u>System open level description&lt;/u>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li>Level A: Open to students who need to use it. They can operate it on their own after training and assessment.&lt;/li>&#xd;
	&lt;li>Level B: Each professor assigns one student to apply for training. The other students of the professor must be operated by the trained students. If a professor has too many students using the instrument, he or she may apply to the person in charge of the instrument to increase the number of students receiving training. .&lt;/li>&#xd;
	&lt;li>Level C: The person in charge of the instrument selects a number of students recommended by the professor to receive training. After passing the assessment, they can operate the instrument themselves and be responsible for entrusted service work.&lt;/li>&#xd;
	&lt;li>Level D: The technical staff of this laboratory accept entrusted services and are not open for use.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model06 clearfix">&#xd;
&lt;div class="table01">&#xd;
&lt;table class="ed_table caption-top" summary="Charges(Unit: NTD)">&#xd;
	&lt;caption>Price list (Unit: NTD)&lt;/caption>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th>Name of Experiment&lt;/th>&#xd;
			&lt;th>with NSTC Project&lt;/th>&#xd;
			&lt;th>without NSTC Project&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">&#xd;
			&lt;ul>&#xd;
				&lt;li>Basic experiment&lt;/li>&#xd;
				&lt;li>Hydrogen Spectrum Experiment&lt;/li>&#xd;
				&lt;li>Carbon spectrum experiment&amp;nbsp;&lt;/li>&#xd;
				&lt;li>No-D experiment&lt;/li>&#xd;
			&lt;/ul>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$120 / 0.5 hour&lt;br />&#xd;
			$60 / piece&lt;br />&#xd;
			$120 / hour&lt;br />&#xd;
			$120 / 0.5 hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$300 / 0.5 hour&lt;br />&#xd;
			$300 / piece&lt;br />&#xd;
			$300 / hour&lt;br />&#xd;
			$600 / 0.5 hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Heteronuclear Experiment&amp;nbsp;&amp;nbsp; &amp;nbsp;&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$200 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$500 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Night and Holiday Experiments&lt;br />&#xd;
			(Reservation is based on 15 hours)&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$60 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$200 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">DOSY/T1/T2 experiment basic fee&lt;br />&#xd;
			(first hour)&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$500 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$2000 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">DOSY/T1/T2 experiment&lt;br />&#xd;
			(from the 2nd hour)&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$200 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$500 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Two-dimensional experiments&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$200 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$500 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Two-dimensional No-D experiments&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$400 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$1000 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">One-dimensional map processing fee&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$20 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$50 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Two-dimensional map processing fee&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$40 / hour&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$100 / hour&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Various temperature experiment&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$400 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$400 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Sample configuration fee&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$300 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$300 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">Liquid N2&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$25/unit&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$25/unit&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">solvent&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$100/unit&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$100/unit&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="111 Annual Fees">postage fee&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$100/unit&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$100/unit&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
Remarks: For experiments with special needs such as variable temperature experiments, please consult the price in advance and make an appointment.&lt;/div>&#xd;
&lt;/div></page4><page5Title/><page5/><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1167399863227256832&amp;init=Y</fileurl><expFile>VARIAN UNITY INOVA 500NMR</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources></resources></item><item><subject>&lt;![CDATA[600 MHz ultra-high magnetic field NMR instrument]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="600 MHz ultra-high magnetic field NMR instrument" src="/ord/en/app/machine/image?module=corefacilities&amp;amp;detailNo=1167402390521909248&amp;amp;init=N" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li>&lt;strong>NMR600&lt;/strong>&lt;br />&#xd;
	Brand model: VARIAN VNMRS-600 NMR SPECTROMETER&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Prof. Wu, Yen-Ku&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 56505&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument consulting and operation services: Dr.&amp;nbsp;Shen, Li-Ching&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 56510&lt;br />&#xd;
	Email &lt;a href="mailto:lc0188@nycu.edu.tw" title="lc0188@nycu.edu.tw">lc0188@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument location: Room 102C, Science Building 2,&amp;nbsp;Guanfu Campus&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-05-21</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, purchase period&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Brand: American VARIAN&lt;/li>&#xd;
	&lt;li class="ed_txt">Model: VNMRS-600&lt;/li>&#xd;
	&lt;li class="ed_txt">Purchase period: June 2011&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Important Specifications&lt;/strong>&lt;br />&#xd;
Liquid NMR spectroscopy, equipped with a superconducting magnet with a magnetic field strength of 14.09 Tesla (600 MHz)&lt;/div>&#xd;
&lt;/div></page1><page2Title>service items</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>service items&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">The instrument is equipped with a low temperature constant temperature system (down to -20 &amp;deg;C), which is suitable for long-term one-dimensional and two-dimensional low temperature experiments.&lt;/li>&#xd;
	&lt;li class="ed_txt">Variable temperature experiment (-80 &amp;deg;C ~ 100 &amp;deg;C).&lt;/li>&#xd;
	&lt;li class="ed_txt">DOSY Spectrum.&lt;/li>&#xd;
	&lt;li class="ed_txt">Special technology of this instrument: please refer to the linked file&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">Note: The temperature change experiment is carried out every Wednesday, please make an appointment by phone (03-5712121 ext. 56510 Ms. Shen Yuqing)&lt;/div>&#xd;
&lt;/div></page2><page3Title>System open level</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>System open level&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Normal working hours: D&lt;/li>&#xd;
	&lt;li class="ed_txt">Night and holiday period: C&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;u>System open level description&lt;/u>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Level A: Open to students who need to use it. They can operate it on their own after training and assessment.&lt;/li>&#xd;
	&lt;li class="ed_txt">Level B: Each professor assigns one student to apply for training. The other students of the professor must be operated by the trained students. If a professor has too many students using the instrument, he or she may apply to the person in charge of the instrument to increase the number of students receiving training. .&lt;/li>&#xd;
	&lt;li class="ed_txt">Level C: The person in charge of the instrument selects a number of students recommended by the professor to receive training. After passing the assessment, they can operate the instrument themselves and be responsible for entrusted service work.&lt;/li>&#xd;
	&lt;li class="ed_txt">Level D: The technical staff of this laboratory accept entrusted services and are not open for use.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page3><page4Title>Management and usage</page4Title><page4>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Management methods and use methods:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">The use of this instrument requires the use of the 【NSTC&amp;nbsp;Basic Research Core Facility Reservation Service Management System】Log in to make an appointment and obtain the electronic appointment serial number before accepting the appointment.&lt;/li>&#xd;
	&lt;li class="ed_txt">Instrument open service includes self-operation and commissioned operation&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Self-operated application process:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Only the Department of Applied Chemistry of our school is open.&lt;/li>&#xd;
	&lt;li class="ed_txt">Users need to submit an application first, and those who pass the onboarding assessment need to sign the [Conclusion Form for the Use of the 600 MHz NMR System of the Guiyi Center of National Yangming Jiaotong University] to qualify for the reservation.&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;strong>Application procedure for entrusted operation:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">a. Only after the online reservation is made to send the order, is the user eligible to use it&lt;/li>&#xd;
	&lt;li class="ed_txt">b. The sample test sequence follows the &amp;quot;first delivery, first testing&amp;quot; method. If you need to rush, you must wait for the technician to coordinate with the first delivery user. If the user does not agree, we will not be able to provide rush service.&lt;/li>&#xd;
	&lt;li class="ed_txt">The entrusted sample delivery and collection can be handled by mail. After the experiment is completed, the paper and electronic files of the atlas will be provided.&lt;/li>&#xd;
	&lt;li class="ed_txt">The optimal concentration of sample preparation is 100mM (carbon spectroscopy can be completed in 1 hour).&lt;/li>&#xd;
	&lt;li class="ed_txt">The instrument room does not provide spectrum analysis services.&lt;/li>&#xd;
	&lt;li class="ed_txt">The maps provided by this instrument room shall not be used for commercial advertising, legal proceedings, or certification.&lt;/li>&#xd;
&lt;/ol&gt;&#xd;
&lt;/div></page4><page5Title>Charges</page5Title><page5>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Charges&lt;/strong>&lt;br />&#xd;
Working hours: Refers to weekdays from 8:00 am to 5:00 pm.&lt;br />&#xd;
Night time: refers to the weekdays from 5:00 pm to 8:00 am the next day.&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Reservations with NSTC projects&#xd;
	&lt;ol>&#xd;
		&lt;li class="ed_txt">Basic experiment：NT$120/0.5 hour&lt;/li>&#xd;
		&lt;li class="ed_txt">2D/heteronuclear experiment：NT$200 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">1H-proton NMR: NT$60 /0.5hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Carbon-13 experiment: NT$120 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Variable temperature experiment: NT$300 / hour / each temperature&lt;/li>&#xd;
		&lt;li class="ed_txt">DOSY/T1/T2 experiment basic fee(first hour): NT$500 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">DOSY/T1/T2 experiment&amp;nbsp;fee(from 2nd hour): NT$200 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Spectrum process fee： 1D&amp;nbsp;NT$20 / piece; 2D&amp;nbsp;&amp;nbsp;NT$40 / piece&lt;/li>&#xd;
		&lt;li class="ed_txt">Night time slot: &amp;nbsp;NT$900/ 15 hours.&lt;/li>&#xd;
	&lt;/ol>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">Reservations without NSTC projects&#xd;
	&lt;ol>&#xd;
		&lt;li class="ed_txt">Basic experiment：NT$300/0.5 hour&lt;/li>&#xd;
		&lt;li class="ed_txt">2D/heteronuclear experiment: NT$500 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">1H-proton NMR: NT$300 /0.5hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Carbon-13 experiment: NT$300 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Variable temperature experiment: NT$1000 / hour / each temperature&lt;/li>&#xd;
		&lt;li class="ed_txt">DOSY/T1/T2 experiment basic fee(first hour): NT$2000 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">DOSY/T1/T2 experiment&amp;nbsp;fee(from 2nd hour): NT$500 / hour&lt;/li>&#xd;
		&lt;li class="ed_txt">Spectrum process fee： 1D&amp;nbsp;NT$50 / piece; 2D&amp;nbsp;&amp;nbsp;NT$100 / piece&lt;/li>&#xd;
		&lt;li class="ed_txt">Night time slot: &amp;nbsp;NT$3000/ 15 hours.&lt;/li>&#xd;
	&lt;/ol>&#xd;
	&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">The instrument room provides paid sample configuration service.&lt;br />&#xd;
&lt;br />&#xd;
Notes:&lt;br />&#xd;
&amp;nbsp;*This laboratory only provides sample matching services. NMR tube and deuterium solvent (CDCl3、D2O、d6-DMSO、d3-acetonitrile、d4-methanol、d6-acetone.) A sample preparation fee of NT$300 will be charged. If the same sample needs to be replaced with a different solvent, the spectrum fee and sample configuration fee will still be charged.&lt;/div>&#xd;
&lt;/div></page5><page6Title>Related files</page6Title><page6>&lt;div class="ed_model17 clearfix ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li class="d-flex">NMR600 opening schedule&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20231101103751290.pdf" rel="noreferrer noopener" target="_blank" title="NMR600 opening schedule(pdf)(Open New Windows)">&lt;img alt="NMR600 opening schedule" src="/userfiles/file/pdf.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="d-flex">Special technology of NMR600&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20231101103832075.pdf" rel="noreferrer noopener" target="_blank" title="Special technology of NMR600(pdf)(Open New Windows)">&lt;img alt="Special technology of NMR600" src="/userfiles/file/pdf.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page6><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1167402390521909248&amp;init=Y</fileurl><expFile>600 MHz ultra-high magnetic field NMR instrument</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources></resources></item><item><subject>&lt;![CDATA[High Resolution Gas Chromatography Mass Spectrometer]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="High Resolution Gas Chromatography Mass Spectrometer" src="/ord/en/app/machine/image?module=corefacilities&amp;amp;detailNo=1168460870024433664&amp;amp;init=N" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li>&lt;strong>High Resolution Gas Chromatograph Mass Spectrometer (HRGCMS)&lt;/strong>&lt;br />&#xd;
	Brand: JEOL, AccuTOF GCX&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Prof.&amp;nbsp;Cheng, Yen-Ju&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 31520&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument consulting and operation services: Ms.&amp;nbsp;Li, Yun-Ming&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 31515&lt;br />&#xd;
	Email &lt;a href="mailto:yunming@nycu.edu.tw" title="yunming@nycu.edu.tw">yunming@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument location: Room 617, Tianjiabing Optoelectronics Center,&amp;nbsp;Guanfu Campus&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-05-21</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, purchase period&lt;/strong>&lt;br />&#xd;
Brand: JEOL&lt;br />&#xd;
Model: AccuTOF GCX&lt;br />&#xd;
Purchase time: 2015.11&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Important Specifications&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Gas chromatograph: Agilent 7890B, which can be connected to mass spectrometer and thermal conductivity detector.&lt;/li>&#xd;
	&lt;li class="ed_txt">Flying mass spectrometer, resolution 10,000FWHM, mass range 4-6,000Da, mass accuracy of 1.5mDa or 4ppm. There are free sources such as EI (electron impact method), CI (chemical free method), FI (field free method), and FD (field desorption method). And there are NIST and WILEY databases for qualitative and quantitative analysis.&lt;/li>&#xd;
	&lt;li class="ed_txt">Autosampler: With liquid and headspace two sampling modes, it can analyze solution and gas samples.&lt;/li>&#xd;
	&lt;li class="ed_txt">Pyrolysis instrument: FRONTIER PY-3030D, temperature range from 80&amp;deg;C to 800&amp;deg;C, with cold focusing function, and equipped with additives and polymer databases, which can perform thermal desorption and thermal cracking of solid and liquid samples and inject GCMS analyze.&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div></page1><page2Title>Service Items and Charges</page2Title><page2>&lt;div class="ed_model06 clearfix">&#xd;
&lt;div class="table01">&#xd;
&lt;table class="ed_table caption-top" summary="Service Items and Charges(Unit: NTD)">&#xd;
	&lt;caption>Service Items and Charges(Unit: NTD)&lt;/caption>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th>service items&lt;/th>&#xd;
			&lt;th>Scope of application and description&lt;/th>&#xd;
			&lt;th>Schedule an appointment&lt;/th>&#xd;
			&lt;th>Unplanned appointment&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Electron Ionization (EI) Mass Spectrometry&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">Hard free source, easy to produce fragmentation, suitable for compounds with molecular weight below 900 that can be heated and vaporized, and can be injected into solid&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">LREI: $100 / piece&lt;br />&#xd;
			HREI: $150 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">LREI: $1000 / piece&lt;br />&#xd;
			HREI: $1,500 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Field Desorption (FD) Mass Spectrometry&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">Soft free source, easy to generate parent ions, suitable for low polarity molecules, it needs to be injected in solution state, the mass range can reach 5000&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">LRFD: $120 / piece&lt;br />&#xd;
			HRFD: $200 / piece&lt;br />&#xd;
			HRFI: $200 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">LRFD: $1,200 / piece&lt;br />&#xd;
			HRFD: $2,000 / piece&lt;br />&#xd;
			HRFI: $2,000 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">chemical ionization (CI) mass spectrometry&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">Soft free source, easy to generate parent ions, suitable for compounds that can be heated and gasified. Use isobutane as reaction gas&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">LRCI: $120 / piece&lt;br />&#xd;
			HRCI: $200 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">LRCI: $1,200 / piece&lt;br />&#xd;
			HRCI: $2,000 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Gas chromatography mass spectrometry (GC/MS)&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">Separation and mass spectrometry identification of small molecule mixtures that can be vaporized at 300 degrees&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">GC-EI-LRMS: $220 / piece&lt;br />&#xd;
			GC-EI-HRMS: $250 / piece&lt;br />&#xd;
			GC-CI-HRMS: $300 / piece&lt;br />&#xd;
			GC-FI-HRMS: $330 / piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">GC-EI-LRMS: $2, 200 / piece&lt;br />&#xd;
			GC-EI-HRMS: $2,500 / piece&lt;br />&#xd;
			GC-CI-HRMS: $3,000 / piece&lt;br />&#xd;
			GC-FI-HRMS: $3,300 / piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Gas Chromatography-Thermal Conductivity (GC-TCD)&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">Hydrogen qualitative, relative quantitative&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">Warm-up fee $100&lt;br />&#xd;
			Sample test $100/piece&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">Warm-up fee $1,000&lt;br />&#xd;
			Sample test $1,000/piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Thermal cracking, thermal desorption gas chromatography mass spectrometry&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">The composition of polymer and material samples is analyzed by thermal cracking and thermal desorption.&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$300/time (including the main signal NIST, Wiley database automatic comparison)&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$3,000/time (including automatic comparison of main signals NIST and Wiley databases)&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">quantitative analysis&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">&#xd;
			&lt;ol>&#xd;
				&lt;li>Establish method and calibration line&lt;/li>&#xd;
				&lt;li>Sample Analysis&lt;/li>&#xd;
				&lt;li>Internal standard method for semi-quantitative&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$1,000 / single target&lt;/li>&#xd;
				&lt;li>Add $300 for each sample or additional target&lt;/li>&#xd;
				&lt;li>Internal standard semi-quantitative basic fee $500&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$10,000 / single target&lt;/li>&#xd;
				&lt;li>Add $3,000 for each sample or additional target&lt;/li>&#xd;
				&lt;li>Semi-quantitative basic fee for internal standard method $5,000&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Manual judgment&lt;/td>&#xd;
			&lt;td data-th="Scope of application and description">HRMS molecular formula estimation, database F-search polymer analysis, interference determination, etc.&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$100 / hour&lt;br />&#xd;
			(At least 2 hours for polymer data interpretation)&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$1,000 / hour&lt;br />&#xd;
			(At least 2 hours for polymer data interpretation)&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page2><page3Title>Opening Hours and Appointments</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Opening schedule:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Monday to Friday 8:00~17:00: Accept entrusted services.&lt;/li>&#xd;
	&lt;li class="ed_txt">The rest of the time: automatic sample injection GCMS detection.&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;br />&#xd;
&lt;strong>Instrument use reservation: please go to NSTC Core Facilities for Basic Research Service Management System (https://vir.nstc.gov.tw/home/Index)&lt;/strong>&lt;strong> or call an operating technician for details&amp;nbsp;&amp;nbsp;&lt;/strong>&lt;/div>&#xd;
&lt;/div></page3><page4Title>Management and usage</page4Title><page4>&lt;div class="ed_model12 clearfix">&#xd;
&lt;div class="item01">&#xd;
&lt;p>1.&lt;/p>&#xd;
For the convenience of off-campus users, the documents can be sent by registered mail. The electronic file of the results will be delivered by e-mail about one week after the samples are received.&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>2.&lt;/p>&#xd;
The tester must attach or describe the following information:&amp;nbsp;&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model13 clearfix">&#xd;
&lt;div class="item02">&#xd;
&lt;p>a.&lt;/p>&#xd;
Measurement item (GC-MS or MS).&lt;/div>&#xd;
&#xd;
&lt;div class="item02"&gt;&#xd;
&lt;p>b.&lt;/p>&#xd;
Free mode (EI, CI, FD, FI).&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>c.&lt;/p>&#xd;
Inferred structural formula, molecular formula and molecular weight. Please indicate the mass range of unknowns. Those who measure altimetry mass spectrometry must attach the molecular formula.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>d.&lt;/p>&#xd;
Solid, liquid or solution can be used, if it is a solution, please inform the estimated concentration.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>e.&lt;/p>&#xd;
A solvent that dissolves the sample.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>f.&lt;/p>&#xd;
For those who test GC-MS, if you have GC test conditions, please attach or inform the possible components. For those who use special columns, please prepare your own columns with an outer diameter of less than 0.32mm, and make an appointment by phone.&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>3.&lt;/p>&#xd;
&lt;strong>In order to maintain the normal operation of the instrument, this instrument is mainly operated by technicians.&lt;/strong>&lt;/div>&#xd;
&lt;/div></page4><page5Title>Related files</page5Title><page5>&lt;div class="ed_model17 clearfix ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">HRGCMS case study &lt;/span> &lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20231030161807634.pdf" target="_blank" title="HRGCMS case study(pdf)(Open New Windows)">&lt;img alt="HRGCMS case study(pdf)(Open New Windows)" src="/userfiles/file/pdf.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1168460870024433664&amp;init=Y</fileurl><expFile>High Resolution Gas Chromatography Mass Spectrometer</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources></resources></item><item><subject>&lt;![CDATA[High Resolution Liquid Chromatography Tandem Mass Spectrometer]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="HIGH RESOLUTION LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETER" src="/ord/en/app/machine/image?module=corefacilities&amp;amp;detailNo=1168474837698482176&amp;amp;init=N" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li>&lt;strong>High Resolution Liquid Chromatography Tandem Mass Spectrometer&lt;/strong>&lt;br />&#xd;
	English abbreviation: UPLC/HRMS/MS&lt;br />&#xd;
	Brand: Bruker, Impact HD, EVOQ&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Prof. Li, Yaw-Kuen&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 31985&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument consultation and operation service: Dr.&amp;nbsp;Huang, Sheng-Cih&lt;/strong>&lt;br />&#xd;
	03-5712121 ext 56574&lt;br />&#xd;
	Email &lt;a href="mailto:redrednctu56574@nycu.edu.tw" title="redrednctu56574@nycu.edu.tw">redrednctu56574@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument location: Room 617, Tianjiabing Optoelectronics Center,&amp;nbsp;Guanfu Campus&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-04-24</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, purchase period&lt;/strong>&lt;br />&#xd;
Brand: Bruker&lt;br />&#xd;
Model: Impact HD , EVOQ&lt;br />&#xd;
Purchase period: 102.11&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Important Specifications&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">&lt;strong>Utimate 3000 ultra-high performance liquid chromatography system: the maximum pressure can reach 15000psi, and the composition of the eluent can be changed step by step to enhance the separation effect.&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>source of ion:&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>A. Electrospray method (ESI): Free highly polar analytes.&lt;/strong>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>B. Atmospheric pressure photodissociation method (APPI): Free the analyte with double bond or benzene ring, which can be photodissociated.&lt;/strong>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>High-resolution mass spectrometer Impact HD: The first section is a quadrupole mass spectrometer, and the second section is a time-of-flight mass spectrometer, with high resolution (40,000FWHM) and mass accuracy (&amp;lt;2ppm). It can also be used with ultra-high performance liquid chromatography system for LCMS or LCMSMS.&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Low-resolution mass spectrometer EVOQ: Quadrupole tandem mass spectrometer, capable of low-resolution ESI-MS and MRM quantitative analysis.&lt;/strong>&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div></page1><page2Title>Service items and opening hours</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Opening hours: Monday to Friday 8:00~17:00; entrusted services are accepted.&lt;br />&#xd;
&lt;br />&#xd;
service items&lt;/strong>&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model12 clearfix">&#xd;
&lt;div class="item01">&#xd;
&lt;p>1.&lt;/p>&#xd;
General services:&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model13 clearfix">&#xd;
&lt;div class="item02">&#xd;
&lt;p>a.&lt;/p>&#xd;
Low-resolution electrospray ionization mass spectrometry (&amp;plusmn;ESI): mass spectrometry determination of highly polar small molecule compounds (MW&amp;lt;2000).&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>b.&lt;/p>&#xd;
High-resolution electrospray ionization mass spectrometry (&amp;plusmn;ESI) and atmospheric pressure photodissociation ionization (APPI) high-resolution accurate mass determination.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>c.&lt;/p>&#xd;
Mass spectrometry tandem method (MS/MS): including full mass spectrometry scanning and product ion scanning, which can analyze the structure of compounds.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>d.&lt;/p>&#xd;
Protein identification: provide mgf files, which can be compared using online MASCOT.&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>2.&lt;/p>&#xd;
Special services:&lt;br />&#xd;
Liquid chromatography mass spectrometry (LC/MS) and liquid chromatography tandem mass spectrometry (LC/MS/MS): Because the selection of liquid chromatography separation columns and conditions is complex and professional and technical, it is listed as a special service item , first contact the operator to discuss the sample properties, and provide the LC separation conditions and even the column.&lt;/div>&#xd;
&lt;/div></page2><page3Title>Management and usage</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Management methods and use methods:&lt;/strong>&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model12 clearfix">&#xd;
&lt;div class="item01">&#xd;
&lt;p>1.&lt;/p>&#xd;
For the convenience of off-campus users, the submitted documents can be sent by registered mail, and the returned documents will be sent by e-mail to transmit the results in the electronic file of the map.&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>2.&lt;/p>&#xd;
The tester must attach or describe the following information:&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model13 clearfix">&#xd;
&lt;div class="item02">&#xd;
&lt;p>a.&lt;/p>&#xd;
Measurement item (free method, positive or negative ion, MS or MS/MS)&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>b.&lt;/p>&#xd;
The estimated structural formula, molecular formula and molecular weight. Please indicate the mass range of unknowns. For those who measure the high resolution mass spectrum, please attach the low resolution mass spectrum.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>c.&lt;/p>&#xd;
It can be solid, liquid or solution. If it is a solution, the concentration should be 1ppm or more than 1 pmole/&amp;mu;l.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>d.&lt;/p>&#xd;
The sample should be soluble in water, methanol or acetonitrile (Acetonitrile) and please specify.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>e.&lt;/p>&#xd;
The analytical sample should not contain radioactive, corrosive, strong acid or alkali, or non-volatile salts such as surfactants and phosphates.&lt;/div>&#xd;
&#xd;
&lt;div class="item02">&#xd;
&lt;p>f.&lt;/p>&#xd;
The protein identification sample must have obvious band when it is stained with Coomassie blue. Please perform enzyme digestion and pass through the C18 desalting tip. If the laboratory needs to replace the C18 desalting tip, an additional 300 yuan will be charged for each piece.&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>3.&lt;/p>&#xd;
In order to maintain the normal operation of the instrument&lt;strong>,This instrument is mainly operated by technicians.&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;div class="item01">&#xd;
&lt;p>4.&lt;/p>&#xd;
In response to the needs of the National Science Council to write the &amp;quot;Annual Work Report and Mid-term Progress Report&amp;quot;, quantify the research results, evaluate the contribution of the school&amp;#39;s service center to academic research, and use the unit&amp;#39;s instruments and equipment. Please mention this unit at any time, and please e-mail the PDF electronic file of the published paper to us in order to apply for the thank you discount (Attachment 1). If the staff of the center (including technicians, moderators, etc.) have made significant contributions to the paper, please also consider including co-authors. Thank you for your help to make this instrument work more smoothly.&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model06 clearfix">&#xd;
&lt;div class="table01">&#xd;
&lt;table class="ed_table caption-top" summary="Charges(Unit: NTD)">&#xd;
	&lt;caption>Charges(Unit: NTD)&lt;/caption>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th>service items&lt;/th>&#xd;
			&lt;th>Service Content&lt;/th>&#xd;
			&lt;th>Use a school&lt;/th>&#xd;
			&lt;th>Schedule an appointment&lt;/th>&#xd;
			&lt;th>Unplanned appointment&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Low Resolution Small Molecule Mass Spectrometry (ESI)&lt;/td>&#xd;
			&lt;td data-th="Service Content">&#xd;
			&lt;ol>&#xd;
				&lt;li>One-time mass spectrometry determination of positive and negative ion electrospraying with molecular weight less than 1250 &amp;nbsp;&lt;/li>&#xd;
				&lt;li>Secondary Mass Spectrometry (MSMS) Determination&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Use a school">chemistry, chemical industry&lt;br />&#xd;
			Life Science Materials Science Medicinal Chemistry&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$200&amp;nbsp;/ piece&lt;/li>&#xd;
				&lt;li>$200 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$1500 / piece&lt;/li>&#xd;
				&lt;li>$1500 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">High resolution and macromolecular mass spectrometry (ESI, APPI)&lt;/td>&#xd;
			&lt;td data-th="Service Content">&#xd;
			&lt;ol>&#xd;
				&lt;li>Provide high-resolution and accurate mass spectrometry and electrospray (ESI) determination of proteins and polymers &amp;nbsp;&lt;/li>&#xd;
				&lt;li>Provide accurate mass spectrometry by atmospheric pressure photodissociation method (APPI)&lt;/li>&#xd;
				&lt;li>Secondary Mass Spectrometry (MSMS) Determination&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Use a school">Chemistry, Chemical Engineering Environmental Science Life Science Materials Science Medicinal Chemistry&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$300 / piece &amp;nbsp;&lt;/li>&#xd;
				&lt;li>$300 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>$2500 / piece &amp;nbsp;&lt;/li>&#xd;
				&lt;li>$2500 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">Ultra-high performance liquid chromatography + high-resolution mass spectrometry (UPLC/HRMS or UPLC/HRMS-MS)&lt;/td>&#xd;
			&lt;td data-th="Service Content">&#xd;
			&lt;ol>&#xd;
				&lt;li>Ultra-high performance liquid chromatography separation &amp;nbsp;&lt;/li>&#xd;
				&lt;li>Full mass spectrometry scan&lt;/li>&#xd;
				&lt;li>Product ion scan&lt;/li>&#xd;
				&lt;li>Elemental composition prediction&lt;/li>&#xd;
				&lt;li>Specify UV wavelength scan&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Use a school">Chemistry, Chemical Engineering Environmental Science Life Science Materials Science Medicinal Chemistry&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">The start-up fee is $700 /0.5 hours.&#xd;
			&lt;ol>&#xd;
				&lt;li>Provide the mass spectrum with the strongest signal at five time points&lt;/li>&#xd;
				&lt;li>For each additional mass spectrogram at a specified time, $20 will be charged&lt;/li>&#xd;
				&lt;li>Add UV: $30 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">The start-up fee is $3500/0.5 hours.&#xd;
			&lt;ol>&#xd;
				&lt;li>Provide the mass spectrum with the strongest signal at five time points&lt;/li>&#xd;
				&lt;li>For each additional mass spectrogram at a specified time, $200 will be charged&lt;/li>&#xd;
				&lt;li>Add UV: $300 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">protein identification&lt;/td>&#xd;
			&lt;td data-th="Service Content">Provide mgf file, which can be compared with online MASCOT.&lt;/td>&#xd;
			&lt;td data-th="Use a school">life sciences&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">$350 / piece&lt;br />&#xd;
			For those who need our laboratory to replace C18 desalting tip, each piece will be charged $30 yuan&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">$3,500 /piece If the laboratory has passed C18 desalting tip on behalf of the laboratory, an additional $300 will be charged for each piece&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">quantitative analysis&lt;/td>&#xd;
			&lt;td data-th="Service Content">&#xd;
			&lt;ol>&#xd;
				&lt;li>Establish method and calibration line&lt;/li>&#xd;
				&lt;li>Sample analysis&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Use a school">Chemistry, Chemical Engineering Environmental Science Life Science Materials Science Medicinal Chemistry&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>Basic fee $1600&lt;/li>&#xd;
				&lt;li>$350 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">&#xd;
			&lt;ol>&#xd;
				&lt;li>Basic fee $8000&lt;/li>&#xd;
				&lt;li>$3500 / piece&lt;/li>&#xd;
			&lt;/ol>&#xd;
			&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td data-th="service items">urgent&lt;/td>&#xd;
			&lt;td data-th="Service Content">Return within 24 hours (need to contact in advance)&lt;/td>&#xd;
			&lt;td data-th="Use a school">&amp;nbsp;&lt;/td>&#xd;
			&lt;td data-th="Schedule an appointment">&amp;nbsp;double the price&lt;/td>&#xd;
			&lt;td data-th="Unplanned appointment">double the price&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page4><page5Title>Related files</page5Title><page5>&lt;div class="ed_model17 clearfix ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">LCMS actual analysis case 20140909 &lt;/span> &lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20231030171845954.pdf" rel="noreferrer noopener" target="_blank" title="LCMS actual analysis case 20140909(pdf)(Open New Windows)">&lt;img alt="LCMS actual analysis case 20140909(pdf)(Open New Windows)" src="/userfiles/file/pdf.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">1040316 Jiaotong University Mass Spectrometer Discount Application Form &lt;/span> &lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20231030172006377.odt" rel="noreferrer noopener" target="_blank" title="1040316 Jiaotong University Mass Spectrometer Discount Application Form(odt)(Open New Windows)">&lt;img alt="1040316 Jiaotong University Mass Spectrometer Discount Application Form(odt)(Open New Windows)" src="/userfiles/file/word.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">LC-MS Application Form-20240111-Manufacturer (Yangming Chiaotung University) &lt;/span>&lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/orden/files/20240112141137864.odt" rel="noreferrer noopener" target="_blank" title="LC-MS Application Form-20210302-Manufacturer (Yangming Jiaotong University)(odt)(Open New Windows)(Open New Windows)">&lt;img alt="LC-MS Application Form-20210302-Manufacturer (Yangming Jiaotong University)(odt)(Open New Windows)" src="/userfiles/file/word.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1168474837698482176&amp;init=Y</fileurl><expFile>HIGH RESOLUTION LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETER</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources></resources></item><item><subject>&lt;![CDATA[Differential scanning calorimetry]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_left">&amp;nbsp;&lt;/div>&#xd;
&#xd;
&lt;div class="ed_pic_right">&lt;img alt="DSC" src="/userfiles/orden/images/20240329120325184.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Differential scanning calorimetry&lt;/span>&lt;/strong>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">English abbreviation: DSC&lt;/span>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Brand: TA, Discovery DSC 2500&lt;/span>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Instrument location: Room 701, Tianjiabing Optoelectronics Center,&amp;nbsp;Guanfu Campus&lt;/strong>&lt;/span>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Instrument expert: &lt;/span>&lt;/strong>&lt;span style="font-size:105%;">Assist. Prof. Chia-Chih Chang&lt;/span>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/span>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Experiment consultation and operation service:&amp;nbsp;&lt;/span>&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/span>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Contact Person:&lt;/span>&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, 03-5712121 ext 56510&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">Operation service：Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/li>&#xd;
			&lt;li class="ed_txt">Experiment consultation：Wang, Li-An&amp;nbsp;&amp;amp; Chu, Yen-Yi&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Sample Delivery&amp;nbsp;Address:&amp;nbsp;&lt;/strong>&lt;/span>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient：Yu, Hsiao-Lei )&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-06-04</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Instrument brand, model, year of purchase&lt;/strong>&lt;/span>&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">Brand: TA&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">Model: Discovery DSC 2500&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">Year of purchase: 2023&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;br />&#xd;
&lt;strong>&lt;span style="font-size:105%;">Important Specifications&lt;/span>&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Baseline flatness (-50 to 300&amp;deg;C)&amp;nbsp;&amp;nbsp;&amp;le;5 &amp;mu;W&lt;/li>&#xd;
	&lt;li class="ed_txt">Baseline repeatability (-50 to 300&amp;deg;C) &amp;nbsp;&amp;nbsp;&amp;lt;10&amp;mu;W&lt;/li>&#xd;
	&lt;li class="ed_txt">Temperature range&amp;nbsp;&amp;nbsp;-90&amp;deg;C to 550&amp;deg;C&lt;/li>&#xd;
	&lt;li class="ed_txt">Temperature accuracy&amp;nbsp; &amp;plusmn;0.025&amp;deg;C&lt;/li>&#xd;
	&lt;li class="ed_txt">Temperature precision &amp;nbsp;&amp;plusmn;0.005&amp;deg;C&lt;/li>&#xd;
	&lt;li class="ed_txt">Enthalpy precision&amp;nbsp;&amp;plusmn;0.04%&lt;br />&#xd;
	&amp;nbsp;&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page1><page2Title>Opening hours and service items</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Opening hours：&lt;/strong>&lt;/span>&lt;strong>Monday to Friday 8:00~17:00; entrusted services are accepted.&lt;/strong>&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Service items&lt;/strong>&lt;/span>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">determine the temperatures and enthalpies of certain transitions based on the raw data.&lt;/li>&#xd;
	&lt;li class="ed_txt">These transitions may include phase changes, melting (crystallization), oxidation, curing, glass transition, or other thermodynamic and kinetic processes.&lt;/li>&#xd;
	&lt;li class="ed_txt">measure the heat capacity of materials.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page2><page3Title>Management  and contacts</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Management of reservations&lt;/strong>&lt;/span>&lt;br />&#xd;
Please make reservations via NSTC Instruments Information System (https://vir.nstc.gov.tw/).&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Contacts:&lt;/strong>&lt;/span>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Instrument expert: Assist. Prof. Chia-Chih Chang&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">Experiment consultation and operation service:&amp;nbsp;&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/li>&#xd;
		&lt;li class="ed_txt">Contact Person:&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, 03-5712121 ext 56510&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">Operation service： Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/li>&#xd;
			&lt;li class="ed_txt">Experiment consultation： Wang, Li-An&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>&lt;span style="color:#8e44ad;">Sample Delivery&amp;nbsp;Address:&amp;nbsp;&lt;br />&#xd;
Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient： Yu,&amp;nbsp;&lt;/span>&lt;/strong>&lt;/span>&lt;span style="color:#8e44ad;">&lt;strong>&lt;span style="font-size:105%;">Hsiao&lt;/span>&lt;/strong>&lt;/span>&lt;span style="font-size:105%;">&lt;strong>&lt;span style="color:#8e44ad;">-Lei )&lt;/span>&lt;/strong>&lt;/span>&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model19 clearfix">&#xd;
&lt;div class="table03">&#xd;
&lt;table class="ed_table caption-top" summary="預設的表格形式">&#xd;
	&lt;caption>Charges(Unit: NTD)&lt;/caption>&#xd;
	&lt;thead>&#xd;
		&lt;tr>&#xd;
			&lt;th rowspan="2">Billing Items&lt;/th>&#xd;
			&lt;th colspan="2" scope="col">Reservation with NSTC project&lt;/th>&#xd;
			&lt;th colspan="2" rowspan="1" scope="col">Reservation without NSTC project&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
		&lt;/tr>&#xd;
	&lt;/thead>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Basic Experiments&lt;/th>&#xd;
			&lt;td data-th="標題A">150 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題B">1100 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Urgent Requests-&lt;/th>&#xd;
			&lt;td data-th="標題A">300 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題B">2200 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Solid Sample Tray&lt;/th>&#xd;
			&lt;td data-th="標題A">80 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題B">80 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Liquid Sample Tray&lt;/th>&#xd;
			&lt;td data-th="標題A">120 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題B">120 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page4><page5Title/><page5/><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1223120764715143168&amp;init=Y</fileurl><expFile>DSC</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources></resources></item><item><subject>&lt;![CDATA[Simultaneous Thermal Analyzers]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="SDT" src="/userfiles/orden/images/20240329142611027.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Simultaneous Thermal Analyzers&lt;/strong>&lt;/span>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">English abbreviation: SDT&lt;/li>&#xd;
		&lt;li class="ed_txt">Brand: TA, SDT 650&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Instrument location: Room 701, Tianjiabing Optoelectronics Center,&amp;nbsp;Guanfu Campus&lt;/span>&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Instrument expert:&amp;nbsp;Assist. Prof. Chia-Chih Chang&lt;/span>&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/span>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Experiment consultation and operation service:&amp;nbsp;&lt;/span>&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/span>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Contact Person:&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, &lt;/span>03-5712121 ext&lt;span style="font-size:105%;"> 56510&lt;/span>&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">&lt;span style="font-size:105%;">Operation service：Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/span>&lt;/li>&#xd;
			&lt;li class="ed_txt">&lt;span style="font-size:105%;">Experiment consultation：Wang, Li-An&amp;nbsp;&lt;/span>&amp;amp; Chu, Yen-Yi&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Sample Delivery&amp;nbsp;Address:&amp;nbsp;&lt;/span>&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient：Yu, Hsiao-Lei )&lt;strong>​&lt;/strong>​​​​​​&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-06-04</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Instrument brand, model, year of purchase&lt;/strong>&lt;/span>&lt;br />&#xd;
Brand: TA&lt;br />&#xd;
Model: SDT 650&lt;br />&#xd;
Year of purchase: 2023&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Important Specifications&lt;/strong>&lt;/span>&lt;br />&#xd;
Temperature Range：Ambient to 750 &amp;deg;C&lt;br />&#xd;
Dynamic Temperature Precision：&amp;plusmn;0.5 &amp;deg;C&lt;br />&#xd;
Heating Rate (Linear)：0.1 to 100 &amp;deg;C/min&lt;br />&#xd;
Calorimetric Accuracy/Precision：&amp;plusmn;2% (based on metal standards)&lt;br />&#xd;
Heat Capacity Accuracy：&amp;plusmn;5%&lt;br />&#xd;
Sample Weight Capacity：200 mg&lt;br />&#xd;
Weighing Accuracy：&amp;plusmn;0.5%&lt;br />&#xd;
Weighing Precision：&amp;plusmn;0.1%&lt;br />&#xd;
Weight Baseline Drift：&amp;nbsp;&amp;lt;50 &amp;micro;g to 1000&amp;deg;C &amp;amp; &amp;lt;50&amp;micro;g 1000 to 1300&amp;deg;C&lt;br />&#xd;
&amp;nbsp;&lt;/div>&#xd;
&lt;/div></page1><page2Title>Opening hours and service items</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Opening hours：&lt;/strong>&lt;/span>Monday to Friday 8:00~17:00; entrusted services are accepted.&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Service items&lt;/strong>&lt;/span>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Modulated DSC&lt;/li>&#xd;
	&lt;li class="ed_txt">Hi-Res TGA&amp;trade;&lt;/li>&#xd;
	&lt;li class="ed_txt">Modulated TGA&amp;trade;&lt;/li>&#xd;
	&lt;li class="ed_txt">Dual Sample Mode&lt;/li>&#xd;
	&lt;li class="ed_txt">Auto-Stepwise TGA&lt;/li>&#xd;
	&lt;li class="ed_txt">Color App-Style Touch Screen&lt;/li>&#xd;
	&lt;li class="ed_txt">EGA Furnace Capable&lt;/li>&#xd;
	&lt;li class="ed_txt">Dual Input Gas-Delivery Manifold&lt;/li>&#xd;
	&lt;li class="ed_txt">Temperature Calibration Curie Point (ASTM E1582)&lt;/li>&#xd;
	&lt;li class="ed_txt">Temperature Calibration Melting Point Standards&lt;br />&#xd;
	&amp;nbsp;&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page2><page3Title>Management and contacts</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Management of reservations&lt;/strong>&lt;/span>&lt;br />&#xd;
Please make reservations via&amp;nbsp;NSTC Instruments Information System&amp;nbsp;(https://vir.nstc.gov.tw/).&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Contacts:&lt;/strong>&lt;/span>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Instrument expert: Assist. Prof. Chia-Chih Chang&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">Experiment consultation and operation service:&amp;nbsp;&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/li>&#xd;
		&lt;li class="ed_txt">Contact Person:&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, 03-5712121 ext 56510&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">Operation service： Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/li>&#xd;
			&lt;li class="ed_txt">Experiment consultation： Wang, Li-An&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>&lt;span style="color:#8e44ad;">Sample Delivery&amp;nbsp;Address:&amp;nbsp;&lt;br />&#xd;
Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient：Yu,&amp;nbsp;Hsiao-Lei )&lt;/span>&lt;/strong>&lt;/span>&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model19 clearfix">&#xd;
&lt;div class="table03">&#xd;
&lt;table class="ed_table caption-top" summary="預設的表格形式">&#xd;
	&lt;caption>Charges(Unit: NTD)&lt;/caption>&#xd;
	&lt;thead>&#xd;
		&lt;tr>&#xd;
			&lt;th rowspan="2">Billing Items&lt;/th>&#xd;
			&lt;th colspan="2" scope="col">Reservation with NSTC project&lt;/th>&#xd;
			&lt;th colspan="2" scope="col">Reservation without NSTC project&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
		&lt;/tr>&#xd;
	&lt;/thead>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Basic Experiments&lt;/th>&#xd;
			&lt;td data-th="標題A">150 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">1100 /hour&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Urgent Requests&lt;/th>&#xd;
			&lt;td data-th="標題A">300 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">2200 /hour&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Solid Sample Tray&lt;/th>&#xd;
			&lt;td data-th="標題A">80 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">80 /piece&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Liquid Sample Tray&lt;/th>&#xd;
			&lt;td data-th="標題A">120 /piece&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">120 /piece&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page4><page5Title/><page5/><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1223156952364748800&amp;init=Y</fileurl><expFile>SDT</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources></resources></item><item><subject>&lt;![CDATA[TAM IV Microcalorimeter system]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="TAM IV" src="/userfiles/orden/images/20240510162527182.jpg" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_title01">&amp;nbsp;&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>TAM IV Microcalorimeter system&lt;/strong>&lt;/span>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">English abbreviation: TAM IV&lt;/span>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Brand: TA, TAM IV Calorimeter&lt;/span>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Instrument location: Room 701, Tianjiabing Optoelectronics Center,&amp;nbsp;Guanfu Campus&lt;/span>&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="font-size:105%;">Instrument expert:&amp;nbsp;Assist. Prof. Chia-Chih Chang&lt;/span>&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/span>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Experiment consultation and operation service:&lt;/strong>&amp;nbsp;&lt;/span>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/span>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;span style="font-size:105%;">Contact Person:&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, &lt;/span>03-5712121 ext&lt;span style="font-size:105%;"> 56510&lt;/span>&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">&lt;span style="font-size:105%;">Operation service：Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/span>&lt;/li>&#xd;
			&lt;li class="ed_txt">&lt;span style="font-size:105%;">Experiment consultation：Wang, Li-An&amp;nbsp;&lt;/span>&amp;amp; Chu, Yen-Yi&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>Sample Delivery&amp;nbsp;Address:&lt;span style="color:#8e44ad;">&amp;nbsp;&lt;/span>&lt;/strong>&lt;/span>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient：Yu, Hsiao-Lei )&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-06-04</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, year of purchase&lt;/strong>&lt;br />&#xd;
Brand: TA&lt;br />&#xd;
Model: TAM IV&lt;br />&#xd;
Year of purchase: 2023&lt;br />&#xd;
&lt;br />&#xd;
&lt;span style="font-size:105%;">&lt;strong>Function&lt;/strong>&lt;/span>&lt;br />&#xd;
TAM IV is the new generation, multi-channel, microcalorimetric system from TA Instruments. TAM offers maximum sensitivity, flexibility, and performance. It can be used with the most sensitive microcalorimeters and a wide variety of accessories to precisely control the experimental conditions. Up to four independent calorimeters can be used simultaneously with TAM IV, to perform repetitive or different types of experiments. TAM IV is totally modular and enables multiple calorimeters to be added to increase sample capacity or functionality. With the addition of a multicalorimeter holding six independent minicalorimeters, the sample throughput is substantially increased. TAM IV employs patented thermostat technology to precisely control the liquid bath temperature to within 0.0001&amp;deg;C, and can be operated in isothermal, step-isothermal or temperature-scanning mode.&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Important Specifications&lt;/strong>&lt;br />&#xd;
1. New temperature control with new response rates provides rapid thermal equilibration and an extended temperature range of 4 &amp;deg;C to 150 &amp;deg;C for real-world cold storage applications.&lt;br />&#xd;
2. Unrivaled temperature stability for accurate heat flow measurements in experiments lasting hours to days and weeks.&lt;br />&#xd;
3. Four calorimeter positions with up to four calorimeters, each operating simultaneously and independently.&lt;/div>&#xd;
&lt;/div></page1><page2Title>Opening hours and service items</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Opening hours：&lt;/strong>Monday to Friday 8:00~17:00; entrusted services are accepted.&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Service items&lt;/strong>&lt;br />&#xd;
1. high-precision measurement of the heat generated or absorbed when a solid or liquid sample dissolves or dilutes in a solvent.&lt;br />&#xd;
2. used for general thermodynamic research as well as quantitative analysis of various solid phases.&lt;br />&#xd;
3.&amp;nbsp;It comes with two containers, 25 ml, and 100 ml, primarily used in conjunction with the TAM IV thermostat with a temperature range of up to 80&amp;deg;C.&lt;/div>&#xd;
&lt;/div></page2><page3Title>Management and contacts</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Management of reservations&lt;/strong>&lt;br />&#xd;
Please make reservations via&amp;nbsp;NSTC Instruments Information System&amp;nbsp;(https://vir.nstc.gov.tw/).&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Contacts:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Instrument expert: Assist. Prof. Chia-Chih Chang&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email：&lt;a href="mailto:mailto:cchang113ac@nycu.edu.tw" title="cchang113ac@nycu.edu.tw">cchang113ac@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">Experiment consultation and operation service:&amp;nbsp;&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Email:&amp;nbsp;&lt;a href="mailto:mailto:567BSTA@gmail.com" title="567BSTA@gmail.com">567BSTA@gmail.com&lt;/a>&lt;/li>&#xd;
		&lt;li class="ed_txt">Contact Person:&amp;nbsp;Dr.&amp;nbsp;Shen, Li-Ching, 03-5712121 ext 56510&#xd;
		&lt;ul>&#xd;
			&lt;li class="ed_txt">Operation service： Chang, Yong-yong &amp;amp; Yu, Hsiao-Lei&lt;/li>&#xd;
			&lt;li class="ed_txt">Experiment consultation： Wang, Li-An&lt;/li>&#xd;
		&lt;/ul>&#xd;
		&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;span style="font-size:105%;">&lt;strong>&lt;span style="color:#8e44ad;">Sample Delivery&amp;nbsp;Address:&amp;nbsp;&lt;br />&#xd;
Room 717, Tianjia-Ping Optoelectronics Building, No. 1001, Daxue Rd. East Dist., Hsinchu City 300093, Taiwan&amp;nbsp;(Recipient： Yu,&amp;nbsp;Hsiao-Lei )&lt;/span>&lt;/strong>&lt;/span>&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model19 clearfix">&#xd;
&lt;div class="table03">&#xd;
&lt;table class="ed_table caption-top" summary="預設的表格形式">&#xd;
	&lt;caption>Charges(Unit: NTD)&lt;/caption>&#xd;
	&lt;thead>&#xd;
		&lt;tr>&#xd;
			&lt;th rowspan="2">&amp;nbsp;&lt;/th>&#xd;
			&lt;th colspan="2" rowspan="1" scope="col">Reservation with NSTC project&lt;/th>&#xd;
			&lt;th colspan="2" rowspan="1" scope="col">Reservation without NSTC project&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
			&lt;th scope="col">Entrusted Operation&lt;/th>&#xd;
			&lt;th scope="col">Self-operation&lt;/th>&#xd;
		&lt;/tr>&#xd;
	&lt;/thead>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Basic Experiments&lt;/th>&#xd;
			&lt;td data-th="標題A">150 /hour&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">300 /hour&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;th scope="row">Whole Day Experiments (longer than 8 hours)&lt;/th>&#xd;
			&lt;td data-th="標題A">1200&lt;/td>&#xd;
			&lt;td data-th="標題B">-&lt;/td>&#xd;
			&lt;td data-th="標題C">2400&lt;/td>&#xd;
			&lt;td data-th="標題C">-&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page4><page5Title/><page5/><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1238413657767940096&amp;init=Y</fileurl><expFile>TAM IV</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1998</relateURL><relateName>Basic Service-Chemistry</relateName></resources></resources></item></ArrayList>