<MachineOpenDataModel><subject>&lt;![CDATA[Fourier Transform Electric Field Orbitrap and Linear Ion Trap Hybrid Mass Spectrometer (LUMOS)]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="Fourier Transform Electric Field Orbitrap and Linear Ion Trap Hybrid Mass Spectrometer" src="/ord/en/app/machine/image?module=corefacilities&amp;amp;detailNo=1167387467540598784&amp;amp;init=N" />&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&#xd;
&lt;div class="ed_list">&#xd;
&lt;ul style="list-style-type: circle;">&#xd;
	&lt;li>&lt;strong>Orbitrap Fusion Lumos Tribrid Mass Spectrometer&lt;/strong>&lt;br />&#xd;
	English abbreviation: Orbitrap Fusion Lumos&lt;br />&#xd;
	Brand: ThermoFisher&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Prof. Tsay,&lt;/strong> &lt;strong>Yeou-Guang&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li>Ext. 67119&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument expert: Dr. Liao,&amp;nbsp;Chen-Chung &lt;/strong>&amp;nbsp;&#xd;
	&lt;ul>&#xd;
		&lt;li>Ext. 67382&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument consultation and operation service: Ms. Huang, Pei-Hsuan &amp;amp; Ms.&amp;nbsp;Li,&amp;nbsp;Jie-Ling&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li>Ext. 67382&lt;/li>&#xd;
		&lt;li>Direct call 02-28267382&lt;/li>&#xd;
		&lt;li>Email &lt;a href="mailto:phhuang@nycu.edu.tw" title="phhuang@nycu.edu.tw">phhuang@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li>&lt;strong>Instrument location: Room 647, Library, Information &amp;amp; Research Building, Yangming Campus&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName>Biology</dataClassName><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-01-16</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Instrument Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument brand, model, purchase period&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Brand: ThermoFisher&lt;/li>&#xd;
	&lt;li class="ed_txt">Model: Orbitrap Fusion&amp;trade; Lumos&amp;trade; Tribrid&amp;trade; Mass Spectrometer&lt;/li>&#xd;
	&lt;li class="ed_txt">Purchase period: 2022&lt;/li>&#xd;
&lt;/ul>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;br />&#xd;
&lt;strong>Important Specifications&lt;/strong>&lt;br />&#xd;
Orbitrap Fusion Lumos also includes a quadrupole mass selector, a two-stage linear ion trap mass analyzer and a Fourier transform electric field orbitrap mass analyzer, equipped with a nano-microflow liquid chromatography system (Vanquish Neo UHPLC), with collision-induced dissociation technology (CID) and high-energy collision-induced dissociation (HCD).&lt;/div>&#xd;
&lt;/div></page1><page2Title>Opening hours</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">&lt;strong>Reservation is required for instrument use: please consult with the administrator to confirm the analysis mode and make a reservation at the&amp;nbsp;&lt;a href="https://vir.nstc.gov.tw/" rel="noreferrer noopener" target="_blank" title="National Science Council Basic Research Core Facility Reservation Service Information System(Open New Windows)">NSTC&amp;nbsp;Basic Research Core Facility Reservation Information&amp;nbsp;Management System&lt;/a>.&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">Samples to be tested can be delivered in person or by package&amp;nbsp;delivery&amp;nbsp;to the office.&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Receiving time: Monday to Friday 9:00~17:00&lt;/li>&#xd;
		&lt;li class="ed_txt">Receiving Address: R648, Library, Information &amp;amp; Research&amp;nbsp;Building, No. 155, Section 2, Linong Street, Beitou District, Taipei City 11221&lt;/li>&#xd;
		&lt;li class="ed_txt">Receiving Unit: Mass Spectrometer Facility of&amp;nbsp;Instrumentation Resource Center, National Yang Ming Chiao Tung University&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;div class="ed_txt">Contact Person: Ms. Huang, Pei-Hsuan&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Tel: 02-28267382&lt;/li>&#xd;
	&lt;li class="ed_txt">Fax: 02-28212863&lt;/li>&#xd;
	&lt;li class="ed_txt">Mail:&amp;nbsp;&lt;a href="mailto:phhuang@nycu.edu.tw" title="phhuang@nycu.edu.tw">phhuang@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page2><page3Title>Service Items and Charges</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Service items and charging standards:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">This mass spectrometer only accepts entrusted services, which are all operated by management personnel, and the instrument is not open for personal operation&lt;/li>&#xd;
	&lt;li class="ed_txt">Confirm the analysis mode with management before sending samples.&lt;/li>&#xd;
	&lt;li class="ed_txt">The sample to be tested must not contain salts and surfactants.&lt;/li>&#xd;
	&lt;li class="ed_txt">The charge for this mass spectrometer is accumulatively billed according to the number of scheduled hours, and it needs to be calculated and registered together with the system cleaning and equilibration time when the instrument is running.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model06 clearfix">&#xd;
&lt;div class="table01">　　 　　 　　 　　 　　 　　&#xd;
&lt;table class="ed_table caption-top" summary="Service items and charging standards">&#xd;
	&lt;caption>Service items and charging standards&lt;/caption>&#xd;
	&lt;tbody>&#xd;
		&lt;tr>&#xd;
			&lt;th>Service items&lt;/th>&#xd;
			&lt;th>Note&lt;/th>&#xd;
			&lt;th>Academic unit&lt;br />&#xd;
			(reservations with NSTC&lt;br />&#xd;
			projects)&lt;/th>&#xd;
			&lt;th>Academic unit&lt;br />&#xd;
			(reservations &lt;em>without&lt;/em> NSTC&lt;br />&#xd;
			projects)&lt;/th>&#xd;
			&lt;th>industry unit&lt;/th>&#xd;
		&lt;/tr>&#xd;
		&lt;tr>&#xd;
			&lt;td class="ed_pc_center" data-th="service items">Mass spectrometer Usage&amp;nbsp;Fee&lt;br />&#xd;
			(Unit: NTD)&lt;/td>&#xd;
			&lt;td data-th="Note">Cumulative charge based on the actual analysis time of the samples (together with the calculation of the system cleaning and equilibrating time).&lt;/td>&#xd;
			&lt;td data-th="academic unit National Science and Technology Association planning appointment fee">$1,200 /hr&lt;/td>&#xd;
			&lt;td data-th="academic unit Non-National Academy of Sciences Plan Appointment Charges">$1,800/hr&lt;/td>&#xd;
			&lt;td data-th="industry unit charges">$3,600 /hr&lt;/td>&#xd;
		&lt;/tr>&#xd;
	&lt;/tbody>&#xd;
&lt;/table>&#xd;
&lt;/div>&#xd;
&lt;/div></page3><page4Title>Management and Usage</page4Title><page4>&lt;div class="ed_model01 clearfix">&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Consult management staff to confirm sample delivery details&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>to &lt;a href="https://vir.nstc.gov.tw/" rel="noreferrer noopener" target="_blank" title="National Science Council Basic Research Core Facility Reservation Service Information System(Open New Windows)">National Science Council Basic Research Core Facility Reservation Service Information System&lt;/a> Make an appointment for the boarding slot and fill in the relevant documents.&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">Send the samples to be tested according to the agreed time period.&lt;/li>&#xd;
	&lt;li class="ed_txt">After receiving the samples, the manager will arrange to board the machine according to the condition of the instrument.&lt;/li>&#xd;
	&lt;li class="ed_txt">Once the analysis is complete, the data can be retrieved.&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div></page4><page5Title>Related Links</page5Title><page5>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;a href="https://www.thermofisher.com/tw/zt/home/industrial/mass-spectrometry/liquid-chromatography-mass-spectrometry-lc-ms/lc-ms-systems/orbitrap-lc-ms/orbitrap-tribrid-mass-spectrometers/orbitrap-fusion-lumos-mass-spectrometer.html" rel="noreferrer noopener" target="_blank" title="ThermoFisher(Open New Windows)">&lt;img alt="ThermoFisher" src="/userfiles/orden/images/thermo.png" />&lt;/a>&lt;br />&#xd;
Official website introduction&lt;/div>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=corefacilities&amp;detailNo=1167387467540598784&amp;init=Y</fileurl><expFile>Fourier Transform Electric Field Orbitrap and Linear Ion Trap Hybrid Mass Spectrometer</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=1990</relateURL><relateName>List of Instruments</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=corefacilities&amp;id=2008</relateURL><relateName>Basic Service-Biology</relateName></resources><resources><relateURL>https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&amp;id=2027&amp;serno=2e6eb727-14c5-46fd-a3bf-680207ed052c</relateURL><relateName>Mass Spectrometry Facility of YM Campus</relateName></resources></resources></MachineOpenDataModel>