{"subject":"[YangMing] Bead Beating Grinder and Lysis System, Fastprep-24 5G","detailContent":"<!-- 直式圖片(調整圖片高度，400px數字可自行依照左側文字適合高度調整) -->\r\n<style type=\"text/css\">.ed_pic_right img {\r\n            max-height: 400px;\r\n            width:auto;\r\n        }\r\n</style>\r\n<div class=\"ed_model05 clearfix\">\r\n<div class=\"ed_pic_right\"><img alt=\"Fastprep-24 5G\" src=\"/userfiles/ordch/images/20241119144741789.jpg\" /></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\"><b>Bead Beating Grinder and Lysis System</b>\r\n\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\">Brand: MP Biomedicals</li>\r\n\t\t<li class=\"ed_txt\">Model: Fastprep-24 5G</li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Location</strong>: Yang-Ming Campus\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong>Room 710-1, Biomedical Building<span style=\"color:#8e44ad;\">&nbsp;</span></strong></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Term of Use: Available&nbsp;anytime on demand</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong><span style=\"color:#e74c3c;\">First-time users must ask the center staff before use.</span></strong></li>\r\n\t\t<li class=\"ed_txt\">Free of charge for NYCU users. Off-campus users, please contact the center before using it.</li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Contact center staff：</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong>Extension：</strong>62382</li>\r\n\t\t<li class=\"ed_txt\"><strong>Email：</strong><a href=\"mailto:ycirc@nycu.edu.tw\" title=\"ycirc@nycu.edu.tw\">ycirc@nycu.edu.tw</a></li>\r\n\t</ul>\r\n\t</li>\r\n</ul>\r\n</div>","dataClassName":null,"pubUnitName":"Instrumentation Resource Center                                                                     ","posterDate":null,"updateDate":"2025-01-15","liaisonper":null,"liaisontel":null,"liaisonfax":null,"liaisonemail":null,"languageurl":null,"page1Title":"Introduction","page1":"<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\">The FastPrep-24 5G is a versatile sample disruption instrument designed to quickly and efficiently homogenize, grind, or lyse biological samples.&nbsp;Samples are added to individual lysing matrix tubes and placed into sample holder adapters within the instrument.&nbsp;The unique, optimized motion of the FastPrep-24 5G shakes the samples in a tridimensional motion resulting in the collision of the sample material with the lysing matrix particles.</div>\r\n</div>\r\n\r\n<div class=\"ed_model02 clearfix\">\r\n<div class=\"ed_title01\">Specifications</div>\r\n\r\n<ol>\r\n\t<li class=\"ed_txt\">Sample Adapter: 24x <strong>2mL</strong>&nbsp;QuickPrep-3 Adapter</li>\r\n\t<li class=\"ed_txt\">Speed Range：4 to 10 m/sec in 0.5 m/sec Increments; (Default: 6 m/sec for QuickPrep-3 Adapter)&nbsp;</li>\r\n\t<li class=\"ed_txt\">Shakes in a tridimensional motion</li>\r\n\t<li class=\"ed_txt\">Time Range：1 to 120 Seconds in 1 Second Increments (Default: 40 Seconds)&nbsp;</li>\r\n\t<li class=\"ed_txt\">Cycles：1 to 9 Cycles (Default: 1 Cycle)&nbsp;</li>\r\n\t<li class=\"ed_txt\">Pause Time During Cycles：1 to 300 Second Pause Between Cycle in 1 Second Increments (Default: 300 Seconds)&nbsp;</li>\r\n\t<li class=\"ed_txt\">Acceleration/Deceleration：&lt;2 seconds to maximum speed or to stop</li>\r\n\t<li class=\"ed_txt\">Pre-Defined Assays：72 Pre-defined and Optimized Assay Programs&nbsp;</li>\r\n</ol>\r\n\r\n<hr class=\"ed_border01\" />\r\n<div class=\"ed_title01\">Major Componenets (Front View)</div>\r\n\r\n<div class=\"ed_txt\"><img alt=\"Front view of Fastprep-24 5G\" src=\"/userfiles/orden/images/20241119172953634.png\" /></div>\r\n</div>\r\n<!-- 直式圖片(調整圖片高度，400px數字可自行依照左側文字適合高度調整) -->\r\n<style type=\"text/css\">.ed_txt img {\r\n            max-height: 500px;\r\n            width:auto;\r\n        }\r\n</style>","page2Title":"Rules of Use","page2":"<div class=\"ed_model01 clearfix\">\r\n<ul>\r\n\t<li class=\"ed_txt\">This machine is on a first-come, first-use basis.&nbsp;<span style=\"color:#e74c3c;\">First-time users should ask the center staff beforehand.</span></li>\r\n\t<li class=\"ed_txt\"><a href=\"https://www.nycu.edu.tw/ord/en/app/machine/doc?module=machine&amp;detailNo=1308972651166830592&amp;type=s\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"FastPrep Manual (English version)(Open New Windows)\">FastPrep Manual (English version) </a></li>\r\n\t<li class=\"ed_txt\"><a href=\"/userfiles/ordch/files/20241119160026282.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Fastprep中文操作手冊(pdf)(開啟新視窗)\">FastPrep Quick Guide Manual (Chinese version)</a></li>\r\n\t<li class=\"ed_txt\">The samples and sample adapter must be adequately secured and balanced before running the Fastprep-24 5G.</li>\r\n\t<li class=\"ed_txt\"><strong>Press the &lsquo;<span style=\"color:#e74c3c;\">Emergency Stop Button</span>&rsquo; and notify the center if the FastPrep-24 5G makes an abnormal sound.</strong></li>\r\n\t<li class=\"ed_txt\">Do not exceed the maximum speed recommended by the Adapter (10 m/s).</li>\r\n\t<li class=\"ed_txt\"><strong><span style=\"color:#e74c3c;\">In case of leakage, clean the machine (do not spray alcohol directly on it)</span> to avoid contamination of the dome and the surrounding area inside the machine; wipe with a paper towel containing distilled water and then dry it with a dry paper towel.</strong></li>\r\n</ul>\r\n</div>","page3Title":"Instructional Video","page3":"<strong>How to <span style=\"color:#008000;\">Unlock</span> the Adapter</strong><br />\r\n<style type=\"text/css\">.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\r\n</style>\r\n<div class=\"embed-container\"><iframe allowfullscreen=\"\" frameborder=\"0\" sandbox=\"allow-scripts allow-same-origin\" src=\"https://www.youtube.com/embed//poNMAvqp65I\" title=\"Unlock\"></iframe></div>\r\n<strong>How to <span style=\"color:#ff0000;\">Lock</span> the Adapter</strong><br />\r\n<style type=\"text/css\">.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\r\n</style>\r\n<div class=\"embed-container\"><iframe allowfullscreen=\"\" frameborder=\"0\" sandbox=\"allow-scripts allow-same-origin\" src=\"https://www.youtube.com/embed//rauceOhyfcM\" title=\"Lock\"></iframe></div>","page4Title":"Related Links","page4":"<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\"><a href=\"https://www.csbiotech.com.tw/product_list3.aspx?prd_id=153\" target=\"_blank\" title=\"Cold Spring Biotech Corp_Fastprep-24 5G(Open New Windows)\"><img alt=\"Cold Spring Biotech Corp_Fastprep-24 5G\" src=\"/userfiles/ordch/images/20231017134322719.jpg\" /></a><br />\r\n<a href=\"https://www.mpbio.com/tw/fastprep-24-5g-instrument?queryID=63994824b9abcd5f8f19fc93d2c4e19b&amp;objectID=48998&amp;indexName=MpBio_Production_Store_tw_products\" target=\"_blank\" title=\"MP Biomedicals_Fastprep-24 5G(Open New Windows)\"><img alt=\"MP Biomedicals_Fastprep-24 5G\" src=\"/userfiles/ordch/images/20241119160504539.jpg\" /></a></div>\r\n</div>","page5Title":null,"page5":null,"page6Title":null,"page6":null,"page7Title":null,"page7":null,"page8Title":null,"page8":null,"docs":[{"fileurl":"https://www.nycu.edu.tw/ord/en/app/machine/doc?module=machine&detailNo=1308972651166830592&type=s","pdffileurl":"","odffileurl":"","expFile":"FastPrep Manual (En)"}],"images":[{"fileurl":"https://www.nycu.edu.tw/ord/en/app/machine/image?module=machine&detailNo=1308362768612593664&init=Y","expFile":"Fastprep-24 5G"}],"videos":[],"audios":[],"resources":[{"relateURL":"https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&id=2023&serno=da69be39-dc4e-48d6-9168-7c96b2dbdb6e","relateName":"Instrument List of YM Campus"},{"relateURL":"https://www.nycu.edu.tw/ord/en/app/machine/list?module=machine&id=2068","relateName":"Other Homogenizing Systems"}]}