<MachineOpenDataModel><subject>&lt;![CDATA[[YangMing] Bead Beating Grinder and Lysis System, Fastprep-24 5G]]&gt;</subject><detailContent>&lt;![CDATA[&lt;!-- 直式圖片(調整圖片高度，400px數字可自行依照左側文字適合高度調整) -->&#xd;
&lt;style type="text/css">.ed_pic_right img {&#xd;
            max-height: 400px;&#xd;
            width:auto;&#xd;
        }&#xd;
&lt;/style>&#xd;
&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="Fastprep-24 5G" src="/userfiles/ordch/images/20241119144741789.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;b>Bead Beating Grinder and Lysis System&lt;/b>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Brand: MP Biomedicals&lt;/li>&#xd;
		&lt;li class="ed_txt">Model: Fastprep-24 5G&lt;/li>&#xd;
	&lt;/ul&gt;&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Location&lt;/strong>: Yang-Ming Campus&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>Room 710-1, Biomedical Building&lt;span style="color:#8e44ad;">&amp;nbsp;&lt;/span>&lt;/strong>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Term of Use: Available&amp;nbsp;anytime on demand&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>&lt;span style="color:#e74c3c;">First-time users must ask the center staff before use.&lt;/span>&lt;/strong>&lt;/li>&#xd;
		&lt;li class="ed_txt">Free of charge for NYCU users. Off-campus users, please contact the center before using it.&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Contact center staff：&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>Extension：&lt;/strong>62382&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>Email：&lt;/strong>&lt;a href="mailto:ycirc@nycu.edu.tw" title="ycirc@nycu.edu.tw">ycirc@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2025-01-15</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">The FastPrep-24 5G is a versatile sample disruption instrument designed to quickly and efficiently homogenize, grind, or lyse biological samples.&amp;nbsp;Samples are added to individual lysing matrix tubes and placed into sample holder adapters within the instrument.&amp;nbsp;The unique, optimized motion of the FastPrep-24 5G shakes the samples in a tridimensional motion resulting in the collision of the sample material with the lysing matrix particles.&lt;/div>&#xd;
&lt;/div>&#xd;
&#xd;
&lt;div class="ed_model02 clearfix">&#xd;
&lt;div class="ed_title01">Specifications&lt;/div>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Sample Adapter: 24x &lt;strong>2mL&lt;/strong>&amp;nbsp;QuickPrep-3 Adapter&lt;/li>&#xd;
	&lt;li class="ed_txt">Speed Range：4 to 10 m/sec in 0.5 m/sec Increments; (Default: 6 m/sec for QuickPrep-3 Adapter)&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">Shakes in a tridimensional motion&lt;/li>&#xd;
	&lt;li class="ed_txt">Time Range：1 to 120 Seconds in 1 Second Increments (Default: 40 Seconds)&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">Cycles：1 to 9 Cycles (Default: 1 Cycle)&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">Pause Time During Cycles：1 to 300 Second Pause Between Cycle in 1 Second Increments (Default: 300 Seconds)&amp;nbsp;&lt;/li>&#xd;
	&lt;li class="ed_txt">Acceleration/Deceleration：&amp;lt;2 seconds to maximum speed or to stop&lt;/li>&#xd;
	&lt;li class="ed_txt">Pre-Defined Assays：72 Pre-defined and Optimized Assay Programs&amp;nbsp;&lt;/li>&#xd;
&lt;/ol>&#xd;
&#xd;
&lt;hr class="ed_border01" />&#xd;
&lt;div class="ed_title01">Major Componenets (Front View)&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;img alt="Front view of Fastprep-24 5G" src="/userfiles/orden/images/20241119172953634.png" />&lt;/div>&#xd;
&lt;/div>&#xd;
&lt;!-- 直式圖片(調整圖片高度，400px數字可自行依照左側文字適合高度調整) -->&#xd;
&lt;style type="text/css">.ed_txt img {&#xd;
            max-height: 500px;&#xd;
            width:auto;&#xd;
        }&#xd;
&lt;/style></page1><page2Title>Rules of Use</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">This machine is on a first-come, first-use basis.&amp;nbsp;&lt;span style="color:#e74c3c;">First-time users should ask the center staff beforehand.&lt;/span>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;a href="https://www.nycu.edu.tw/ord/en/app/machine/doc?module=machine&amp;amp;detailNo=1308972651166830592&amp;amp;type=s" rel="noreferrer noopener" target="_blank" title="FastPrep Manual (English version)(Open New Windows)">FastPrep Manual (English version) &lt;/a>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;a href="/userfiles/ordch/files/20241119160026282.pdf" rel="noreferrer noopener" target="_blank" title="Fastprep中文操作手冊(pdf)(開啟新視窗)">FastPrep Quick Guide Manual (Chinese version)&lt;/a>&lt;/li>&#xd;
	&lt;li class="ed_txt">The samples and sample adapter must be adequately secured and balanced before running the Fastprep-24 5G.&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Press the &amp;lsquo;&lt;span style="color:#e74c3c;">Emergency Stop Button&lt;/span>&amp;rsquo; and notify the center if the FastPrep-24 5G makes an abnormal sound.&lt;/strong&gt;&lt;/li>&#xd;
	&lt;li class="ed_txt">Do not exceed the maximum speed recommended by the Adapter (10 m/s).&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>&lt;span style="color:#e74c3c;">In case of leakage, clean the machine (do not spray alcohol directly on it)&lt;/span> to avoid contamination of the dome and the surrounding area inside the machine; wipe with a paper towel containing distilled water and then dry it with a dry paper towel.&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page2><page3Title>Instructional Video</page3Title><page3>&lt;strong>How to &lt;span style="color:#008000;">Unlock&lt;/span> the Adapter&lt;/strong>&lt;br />&#xd;
&lt;style type="text/css">.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }&#xd;
&lt;/style>&#xd;
&lt;div class="embed-container">&lt;iframe allowfullscreen="" frameborder="0" sandbox="allow-scripts allow-same-origin" src="https://www.youtube.com/embed//poNMAvqp65I" title="Unlock">&lt;/iframe>&lt;/div>&#xd;
&lt;strong>How to &lt;span style="color:#ff0000;">Lock&lt;/span> the Adapter&lt;/strong>&lt;br />&#xd;
&lt;style type="text/css">.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }&#xd;
&lt;/style>&#xd;
&lt;div class="embed-container">&lt;iframe allowfullscreen="" frameborder="0" sandbox="allow-scripts allow-same-origin" src="https://www.youtube.com/embed//rauceOhyfcM" title="Lock">&lt;/iframe>&lt;/div></page3><page4Title>Related Links</page4Title><page4>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;a href="https://www.csbiotech.com.tw/product_list3.aspx?prd_id=153" target="_blank" title="Cold Spring Biotech Corp_Fastprep-24 5G(Open New Windows)">&lt;img alt="Cold Spring Biotech Corp_Fastprep-24 5G" src="/userfiles/ordch/images/20231017134322719.jpg" />&lt;/a>&lt;br />&#xd;
&lt;a href="https://www.mpbio.com/tw/fastprep-24-5g-instrument?queryID=63994824b9abcd5f8f19fc93d2c4e19b&amp;amp;objectID=48998&amp;amp;indexName=MpBio_Production_Store_tw_products" target="_blank" title="MP Biomedicals_Fastprep-24 5G(Open New Windows)">&lt;img alt="MP Biomedicals_Fastprep-24 5G" src="/userfiles/ordch/images/20241119160504539.jpg" />&lt;/a>&lt;/div>&#xd;
&lt;/div></page4><page5Title/><page5/><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs><docs><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/doc?module=machine&amp;detailNo=1308972651166830592&amp;type=s</fileurl><pdffileurl></pdffileurl><odffileurl></odffileurl><expFile>FastPrep Manual (En)</expFile></docs></docs><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=machine&amp;detailNo=1308362768612593664&amp;init=Y</fileurl><expFile>Fastprep-24 5G</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&amp;id=2023&amp;serno=da69be39-dc4e-48d6-9168-7c96b2dbdb6e</relateURL><relateName>Instrument List of YM Campus</relateName></resources><resources><relateURL>https://www.nycu.edu.tw/ord/en/app/machine/list?module=machine&amp;id=2068</relateURL><relateName>Other Homogenizing Systems</relateName></resources></resources></MachineOpenDataModel>