<MachineOpenDataModel><subject>&lt;![CDATA[[YangMing] Cryostat Microtome - epredia (Thermo)]]&gt;</subject><detailContent>&lt;![CDATA[&lt;!-- 直式圖片(調整圖片高度，400px數字可自行依照左側文字適合高度調整) -->&#xd;
&lt;style type="text/css">.ed_pic_right img,&#xd;
    .ed_pic img {&#xd;
        max-height: 400px;&#xd;
        width:auto;&#xd;
    }&#xd;
&lt;/style>&#xd;
&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="Thermo (espredia) NX50 Nx70" src="/userfiles/orden/images/20240306141529386.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;strong>Cryostat Microtome&lt;/strong>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Brand: epredia (Thermo)&lt;/li>&#xd;
		&lt;li class="ed_txt">Model: CryoStar &amp;nbsp;NX70&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Location&lt;/strong>: Yang-Ming Campus&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>Room 465, Biomedical Engineering Building&amp;nbsp;&lt;span style="color:#8e44ad;">(I Machine-NX70)&lt;/span>&lt;/strong>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>Room 710, Biomedical Building&lt;span style="color:#8e44ad;"> (J Machine-NX70)&lt;/span>&lt;/strong>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>Room 615, Library, Information &amp;amp; Research Building&lt;span style="color:#8e44ad;">&amp;nbsp;(H Machine-NX70)&lt;/span>&lt;/strong>&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>Room B02, Shou-Ren Building&lt;span style="color:#8e44ad;">&amp;nbsp;(K Machine-NX70)&lt;/span>&lt;/strong>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Term of use: Reservation required&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Free of charge for NYCU students and faculties.&amp;nbsp;For off-campus users, please contact the center staff before use.&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Reservation &amp;gt;&amp;gt;&amp;gt; &lt;a href="https://ircbooking.nycu.edu.tw/IRC/irc_booking/index_en.aspx" rel="noreferrer noopener" target="_blank" title="Instrument Reservation System(Open New Windows)">Instrument Reservation System&lt;/a>&lt;/strong>&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Contact center staff：&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">&lt;strong>Extension：&lt;/strong>62382&lt;/li>&#xd;
		&lt;li class="ed_txt">&lt;strong>Email：&lt;/strong>&lt;a href="mailto:ycirc@nycu.edu.tw" title="ycirc@nycu.edu.tw">ycirc@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-02-11</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">The scope of application of this machine is as follows:&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">For fresh tissue sections.&lt;/li>&#xd;
		&lt;li class="ed_txt">Slicing range 0.5-500 um&lt;/li>&#xd;
		&lt;li class="ed_txt">Specimen head temperature set to -45&amp;deg;C&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page1><page2Title>Instructions</page2Title><page2>&lt;span style="font-size:110%;">Before use:&lt;/span>&#xd;
&lt;ol>&#xd;
	&lt;li>Please register your and your instructor&amp;#39;s names in the registration book. Ensure the machine is in good condition and the cryochamber is clean.&lt;/li>&#xd;
	&lt;li>&lt;strong>Quick freezing of the specimen&lt;/strong>:&#xd;
	&lt;ol>&#xd;
		&lt;li>Activate the &amp;ldquo;Cryobar&amp;rdquo; button on the control panel.&lt;/li>&#xd;
		&lt;li>Use a freezing compound (such as OCT) to fix the specimen onto the Object Disc (specimen holder)&lt;/li>&#xd;
		&lt;li>Place the Object Disc (specimen holder) on the Cryobar to freeze the specimen.&lt;/li>&#xd;
	&lt;/ol>&#xd;
	&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;span style="font-size:110%;">After use:&lt;/span>&#xd;
&#xd;
&lt;ol>&#xd;
	&lt;li>Clean the used Object Disc (specimen holder) and return it to its original location if you borrow it from the center.&lt;/li>&#xd;
	&lt;li>&lt;strong>Place back the protective cover of the Blade Holder.&lt;/strong>&lt;/li>&#xd;
	&lt;li>&lt;strong>Clean the remaining residual glue and specimen inside the cryochamber.&lt;/strong>&lt;/li>&#xd;
	&lt;li>Tighten the handle clamps.&lt;/li>&#xd;
	&lt;li>Close the window of cryochamber.&lt;/li>&#xd;
	&lt;li>&lt;strong>Press Stand-by on the control panel.&lt;/strong>&lt;/li>&#xd;
&lt;/ol></page2><page3Title>Reservation rules and precautions</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;ol>&#xd;
	&lt;li class="ed_txt">Reservations must be made online using the &lt;a href="https://ircbooking.nycu.edu.tw/IRC/irc_booking/index_en.aspx" rel="noreferrer noopener" target="_blank" title="Instrument Reservation System(Open New Windows)">Instrument Reservation System&lt;/a> before use.&lt;/li>&#xd;
	&lt;li class="ed_txt">Reservations can be made as early as two weeks in advance. Each user can book two sessions in 2 weeks, with a maximum of five hours for each session.&lt;/li>&#xd;
	&lt;li class="ed_txt">For general operation training, please contact the center&amp;#39;s staff for demonstration.&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="color:#ff0000;">Please use the original labeled Object Disc (specimen chuck), and do not take the borrowed Object Disc and related items away from the Center.&lt;/span>&lt;/li>&#xd;
	&lt;li class="ed_txt">Do not turn off the main switch of the machine.&lt;/li>&#xd;
	&lt;li class="ed_txt">Please keep it clean and functional for all students and faculty.&lt;/li>&#xd;
	&lt;li class="ed_txt">Please read the user&amp;#39;s manual before use.&lt;/li>&#xd;
	&lt;li class="ed_txt">Please do not leave your belongings inside the cryochamber after use, and take away the used blades and waste.&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;span style="color:#ff0000;">Please bring your own anti-roll plate!&lt;/span>&lt;/li>&#xd;
&lt;/ol>&#xd;
&lt;/div></page3><page4Title>Manuals and Instructional Videos</page4Title><page4>&lt;div class="ed_model17 clearfix ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">X70 Manual (English version)&lt;/span>&lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&amp;nbsp;&lt;/li>&#xd;
		&lt;li>&lt;a href="/userfiles/ordch/files/20231018135651505.pdf" rel="noreferrer noopener" target="_blank" title="NX70 English Manual(pdf)(Open New Windows)(Open New Windows)">&lt;img alt="NX70 English Manual(pdf)(Open New Windows)" src="/userfiles/file/pdf.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">Operation Instruction Video (editing)&lt;/span>&lt;/span>&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="#" rel="noreferrer noopener" target="_blank" title="Operation video(Open New Windows)">&lt;img alt="Operation video" src="/userfiles/file/link.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page4><page5Title>Related Links</page5Title><page5>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;a href="https://epredia.com/solutions/cryotomy-solutions/" rel="noreferrer noopener" target="_blank" title="epredia(Open New Windows)">&lt;img alt="epredia" src="/userfiles/ordch/images/20231219165432452.png" />&lt;/a>&lt;/div>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=machine&amp;detailNo=1167347955041046528&amp;init=Y</fileurl><expFile>Cryostat Microtome - epredia (Thermo)</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&amp;id=2023&amp;serno=da69be39-dc4e-48d6-9168-7c96b2dbdb6e</relateURL><relateName>Instrument List of YM Campus</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/list?module=machine&amp;id=2062</relateURL><relateName>Other Microtomes</relateName></resources></resources></MachineOpenDataModel>