<MachineOpenDataModel><subject>&lt;![CDATA[[Guangfu] Powder X-ray Diffractometer]]&gt;</subject><detailContent>&lt;![CDATA[&lt;div class="ed_model05 clearfix">&#xd;
&lt;div class="ed_pic_right">&lt;img alt="X-ray powder diffractometer" src="/userfiles/ordch/images/20231017142817402.jpg" />&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">&lt;strong>Powder X-ray Diffractometer&lt;/strong>&#xd;
&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Brand/model: Germany, Bruker AXS GmbH, D8 Advance&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Expert: Prof. Lee, Chi-Shen&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Ext 31332&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Manager: Xu&lt;/strong>,&amp;nbsp;&lt;strong>Yu-Xiang&lt;/strong>&#xd;
	&lt;ul>&#xd;
		&lt;li class="ed_txt">Ext 31333&lt;/li>&#xd;
		&lt;li class="ed_txt">Email:&amp;nbsp;&lt;a href="mailto:mailto:nycu313654076.sc13@nycu.edu.tw" title="nycu313654076.sc13@nycu.edu.tw">nycu313654076.sc13@nycu.edu.tw&lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
	&lt;li class="ed_txt">&lt;strong>Instrument Location: Room 102A, Science Building 2&lt;/strong>&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>]]&gt;</detailContent><dataClassName/><pubUnitName>Instrumentation Resource Center                                                                     </pubUnitName><posterDate/><updateDate>2026-04-28</updateDate><liaisonper/><liaisontel/><liaisonfax/><liaisonemail/><languageurl/><page1Title>Introduction</page1Title><page1>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Instrument and equipment description:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt" style="margin-left: 40px;">Brand/Model: Germany, Bruker AXS GmbH, D8 Advance&lt;br />&#xd;
Year and month of instrument purchase: 2003.09.01&lt;/div>&#xd;
&#xd;
&lt;div class="ed_txt">&lt;br />&#xd;
&lt;strong>Important Specifications:&lt;/strong>&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Bragg&amp;ndash;Brentano type&lt;/li>&#xd;
	&lt;li class="ed_txt">&amp;theta;-2&amp;theta; scan&lt;/li>&#xd;
	&lt;li class="ed_txt">Cu K&amp;alpha; (&amp;lambda; = 1.5418 &amp;Aring;)&amp;nbsp;without monochromator&lt;/li>&#xd;
	&lt;li class="ed_txt">0.6 mm&amp;nbsp;incident slits&lt;/li>&#xd;
	&lt;li class="ed_txt">Vantec-1 detector&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page1><page2Title>Service Items and Opening Hours</page2Title><page2>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">&lt;strong>Services:&lt;/strong>&lt;br />&#xd;
Measure X-ray diffraction of powder, bulk, and film materials.&lt;br />&#xd;
X-ray diffraction database PDF-2.&lt;br />&#xd;
&lt;br />&#xd;
&lt;strong>Opening Hours:&lt;/strong>&lt;br />&#xd;
Monday to Friday 10:00-12:00 am and 1:00-5:00 pm&lt;/div>&#xd;
&lt;/div></page2><page3Title>System Open Level</page3Title><page3>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">Graduate students in the master&amp;#39;s and doctoral programs at our school who have completed the 3-hour radiation safety training, obtained the radiation safety seal, received operational training, and passed the examination are eligible to schedule appointments to operate the instrument independently.&lt;br />&#xd;
&lt;br />&#xd;
Commissioned measurements are also permitted.&lt;/div>&#xd;
&lt;/div></page3><page4Title>Charges</page4Title><page4>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">Charges are based on the time spent using X-rays and computer operations. Each hour is considered one unit. The pricing is as follows:&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">Self-operated NYCU users are charged NT$300 per hour.&lt;/li>&#xd;
	&lt;li class="ed_txt">Commissioned measurement NYCU users are charged NT$600 per hour.&lt;/li>&#xd;
	&lt;li class="ed_txt">Off-campus self-operated users are charged NT$600 per hour.&lt;/li>&#xd;
	&lt;li class="ed_txt">Off-campus&amp;nbsp;commissioned measurements are charged NT$1000 per hour.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page4><page5Title>Management and Usage Methods</page5Title><page5>&lt;div class="ed_model01 clearfix">&#xd;
&lt;div class="ed_txt">Novice education training requires an additional appointment with the instrument administrator. Once the training is completed, you will be qualified to schedule self-operation appointments. It is available to NYCU users during working hours, excluding instrument maintenance periods.&lt;br />&#xd;
&lt;br />&#xd;
Here are some guidelines:&lt;/div>&#xd;
&#xd;
&lt;ul>&#xd;
	&lt;li class="ed_txt">It is preferred to use powder for the sample, but blocks and films are also acceptable.&lt;/li>&#xd;
	&lt;li class="ed_txt">Block samples should not exceed 2.0&amp;times;0.7&amp;times;0.1 cm&lt;sup>3&lt;/sup> or 1.0&amp;times;1.0&amp;times;0.2 cm&lt;sup>3&lt;/sup>.&lt;/li>&#xd;
	&lt;li class="ed_txt">We will not accept radioactive, highly toxic, or volatile samples.&lt;/li>&#xd;
	&lt;li class="ed_txt">Data can be saved online, or bring your own flash drive.&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div>&#xd;
&amp;nbsp;&#xd;
&#xd;
&lt;div class="ed_model17 clearfix ed_list">&#xd;
&lt;ul>&#xd;
	&lt;li class="d-flex">&lt;span style="vertical-align: inherit;">&lt;span style="vertical-align: inherit;">X-ray powder diffractometer commissioned measurement application form&lt;/span> &lt;/span>&#xd;
&#xd;
	&lt;ul class="d-flex">&#xd;
		&lt;li>&lt;a href="/userfiles/ordch/files/20231017143127931.odt" rel="noreferrer noopener" target="_blank" title="X-ray powder diffractometer commissioned measurement application form (odt) (open new Window)">&lt;img alt="X-ray powder diffractometer commissioned measurement application form" src="/userfiles/file/odt.png" /> &lt;/a>&lt;/li>&#xd;
	&lt;/ul>&#xd;
	&lt;/li>&#xd;
&lt;/ul>&#xd;
&lt;/div></page5><page6Title/><page6/><page7Title/><page7/><page8Title/><page8/><docs/><images><images><fileurl>https://www.nycu.edu.tw/ord/en/app/machine/image?module=machine&amp;detailNo=1167359443617189888&amp;init=Y</fileurl><expFile>Powder X-ray Diffractometer</expFile></images></images><videos/><audios/><resources><resources><relateURL>https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&amp;id=2021&amp;serno=ebdd9934-00ef-4bee-9a8a-11f305100505</relateURL><relateName>Instrument List of Guanfu and Boai Campus</relateName></resources><resources><relateURL>https://www.nycu.edu.tw/ord/en/app/machine/list?module=machine&amp;id=2044</relateURL><relateName>Other Diffratometers</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/view?module=corefacilities&amp;id=1990&amp;serno=5807794d-d0fa-44a5-aa3d-bcd0d562c90a</relateURL><relateName>[NSTC Basic Research Core Facility] Low Temperature XRD</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/view?module=corefacilities&amp;id=1990&amp;serno=8a889c9c-790f-435d-9435-29c8849028cc</relateURL><relateName>[NSTC Basic Research Core Facility] FE-TEM, JEM-F200</relateName></resources><resources><relateURL>https://ord.nycu.edu.tw/ord/en/app/machine/view?module=corefacilities&amp;id=1990&amp;serno=2835c5fb-0a2a-43a2-9fa5-e783aad9b95c</relateURL><relateName>[NSTC Basic Research Core Facility] JEOL JSM-7800 Prime SEM</relateName></resources></resources></MachineOpenDataModel>