{"subject":"[YangMing] Multifunctional Microplate Reader: TECAN SPARK","detailContent":"<div class=\"ed_model05 clearfix\">\r\n<div class=\"ed_pic_right\"><img alt=\"Multifunctional Micro Disc Analyzer TECAN SPARK\" src=\"/userfiles/ordch/images/20231016111748134.jpg\" /></div>\r\n\r\n<ul>\r\n\t<li class=\"ed_txt\"><strong>Multimode microplate readers</strong></li>\r\n\t<li class=\"ed_txt\"><strong>Brand Model: </strong>TECAN SPARK</li>\r\n\t<li class=\"ed_txt\"><strong>Instrument Location:&nbsp;</strong>Yang-Ming Campus\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong>Room 465, 4th floor, Biomedical Engineering Building &nbsp;<span style=\"color:#9b59b6;\">(H machine)</span> </strong></li>\r\n\t\t<li class=\"ed_txt\"><strong>Room B02, B1 floor, Shou-ren Building <span style=\"color:#9b59b6;\">(I machine)</span> </strong></li>\r\n\t\t<li class=\"ed_txt\"><strong>Room 701, 7th floor, Biomedical Building <span style=\"color:#9b59b6;\">(J machine)</span></strong></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Term of Use: Available anytime&nbsp;</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><span style=\"color:#e74c3c;\">Machine J of the Biomedical Building is open for weekend long-term experiments. Please make online reservations through the &quot;<a href=\"https://ircbooking.nycu.edu.tw/IRC/irc_booking/index_en.aspx\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Instrument Reservation System(Open New Windows)\">Instrument Reservation System</a>.&quot;</span></li>\r\n\t\t<li class=\"ed_txt\">Free of charge for NYCU users. Off-campus users, please contact the center before use.</li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"ed_txt\"><strong>Contact center staff：</strong>\r\n\t<ul>\r\n\t\t<li class=\"ed_txt\"><strong>Extension：</strong>62382</li>\r\n\t\t<li class=\"ed_txt\"><strong>Email：</strong><a href=\"mailto:ycirc@nycu.edu.tw\" title=\"ycirc@nycu.edu.tw\">ycirc@nycu.edu.tw</a></li>\r\n\t</ul>\r\n\t</li>\r\n</ul>\r\n</div>","dataClassName":null,"pubUnitName":"Instrumentation Resource Center                                                                     ","posterDate":null,"updateDate":"2025-01-15","liaisonper":null,"liaisontel":null,"liaisonfax":null,"liaisonemail":null,"languageurl":null,"page1Title":"Introduction","page1":"<div class=\"ed_model12 clearfix\">\r\n<div class=\"item01\">\r\n<p><strong>I.</strong></p>\r\n<strong>&nbsp;Instrument Specifications</strong>\r\n\r\n<ol>\r\n\t<li>The system utilizes a high-energy Xenon flash lamp as its light source. This lamp has a notable long lifespan and requires no pre-use warming.</li>\r\n\t<li>The flash frequency of the Xenon bulb can be tailored to suit various detection modes.</li>\r\n\t<li>Compatible with up to three detectors, the system allows the optimal detector to be chosen based on the detection mode.</li>\r\n\t<li>Accommodates sample formats ranging from 6 to 384 microwell plates without changing the Plate Adapter or Plate Holder for different plate sizes.</li>\r\n\t<li>Offers continuous full-wavelength screening via a quadruple splitting system, eliminating the need for additional filters.</li>\r\n\t<li>Features the Quad4 Monochromator optical system for effective stray light filtration, up to a factor of 10<sup>-6</sup>, with rapid and precise scanning facilitated by rotating the Monochromator Mirror.</li>\r\n\t<li>It provides three oscillation modes: linear, orbital, or double orbital shaking, with 11 amplitude frequency levels (330 rpm to 1440 rpm) adjustable by 0.5 mm increments.</li>\r\n\t<li>Allows for direct operation on the panel, including microplate insertion and removal, without requiring a computer.</li>\r\n\t<li>Delivers rapid measurement speeds: less than 13 seconds for a 96-well plate and less than 30 seconds for a 384-well plate.</li>\r\n\t<li>Includes a built-in power supply.</li>\r\n\t<li>Automatically adapts to voltages between 120 and 240 volts.</li>\r\n\t<li>Equipped with a USB 2.0 interface for connectivity.</li>\r\n\t<li>Features a temperature control range from room temperature +4 to 42℃&plusmn;0.5℃.</li>\r\n\t<li>Designed as a fully modular system, it allows for significant expansion flexibility.</li>\r\n</ol>\r\n</div>\r\n\r\n<div class=\"item01\">\r\n<p><strong>II.</strong></p>\r\n<strong>&nbsp;Absorbance Measurement</strong>\r\n\r\n<ol>\r\n\t<li>Independent optical system, dedicated high-speed Monochromator and detector</li>\r\n\t<li>Wavelength range: 200 &ndash; 1000 nm (UV/VIS/NIR)</li>\r\n\t<li>Measurement range: 0 &ndash; 4 OD.</li>\r\n\t<li>Detector module: UV Silicon photodiode</li>\r\n\t<li>Detection accuracy: @260 &lt;0.5 %</li>\r\n\t<li>Detection precision: @260 &lt;0.2 %</li>\r\n\t<li>Wavelength accuracy: ≦0.8 nm</li>\r\n\t<li>Wavelength reproducibility: ≦0.5 nm</li>\r\n\t<li>200-1000nm spectrum scanning speed: ≦5 sec</li>\r\n</ol>\r\n</div>\r\n\r\n<div class=\"item01\">\r\n<p>III.</p>\r\n<strong>&nbsp;Full Wavelength Fluorescence Measurement</strong>\r\n\r\n<ol>\r\n\t<li>Measurement mode: Supports upper and lower readings and time-lag fluorescence measurement mode.</li>\r\n\t<li>Wavelength range: Excitation range from 230-900nm, while emission range from 280-900nm.</li>\r\n\t<li>Adjustable Bandwidth: from 5 &ndash; 50nm, with options for 5, 7.5, 10, 15, 20, 25, 30, or 50nm.</li>\r\n\t<li>Measurement range: from 0 to 60,000 RFU.</li>\r\n\t<li>PMT detector module: Includes independent PMT, UV, and red-sensitive modules.</li>\r\n\t<li>Fluorescence magnification Gain value setting: You can choose automatic adjustment (automatic analysis of the entire plate, analysis of specified hole positions, or enhanced dynamic range) or manual setting, and the range of 0~255 can be adjusted arbitrarily.</li>\r\n\t<li>Fluorescence sensitivity: The upper reading is 20amol/well, while the lower reading is 0.2 fmol/well.</li>\r\n\t<li>Time-lag fluorescence measurement sensitivity: 0.7amol/well.</li>\r\n\t<li>Wavelength accuracy: &plusmn; 0.5 nm for ≦315nm and &gt;315 nm.</li>\r\n\t<li>During the upper reading experiment, the Z-position is automatically adjusted by 1&mu;m to obtain the best fluorescence reading position. This adjustment is based on the difference in liquid level and helps determine the optimal fluorescence signal and background value. A diagram represents the high position.</li>\r\n</ol>\r\n</div>\r\n\r\n<div class=\"item01\">\r\n<p><strong>IV.&nbsp;</strong></p>\r\n<strong>Luminescence measurement</strong>\r\n\r\n<ol>\r\n\t<li>Wavelength range: 300-700 nm</li>\r\n\t<li>Detector module: Independent Photon Counting System with low dark current PMT, single photon counter, which can accurately detect luminescence readings with weak signals.</li>\r\n\t<li>Built-in Attenuation filter, effective detection dynamic range up to 109</li>\r\n\t<li>Glow Luminescence detection sensitivity: 225 amol ATP/well,</li>\r\n\t<li>Flash Luminescence detection sensitivity: 12 amol ATP/well</li>\r\n\t<li>Integration Time/well: 1~20000 ms</li>\r\n\t<li>The reading head&#39;s height can be adjusted automatically to the optimal Z-position reading height depending on the type of microplates used. This reduces the mutual interference caused by the self-illumination of luminescence samples, thereby improving luminescence detection sensitivity.</li>\r\n\t<li>Cross Talk: 0.01%</li>\r\n\t<li>Built-in long pass and short pass filters, supporting 19-band multi-color luminescence detection mode</li>\r\n</ol>\r\n</div>\r\n</div>","page2Title":"Software Applications","page2":"<div class=\"ed_model01 clearfix\">\r\n<ol>\r\n\t<li class=\"ed_txt\">The software offers an intuitive, wizard-style guided operation interface that significantly improves work efficiency.</li>\r\n\t<li class=\"ed_txt\">It supports Endpoint, Kinetic, Multilabel, and more experiments.</li>\r\n\t<li class=\"ed_txt\">All experimental parameters and settings are conveniently displayed in the same window.</li>\r\n\t<li class=\"ed_txt\">The workflow-oriented software allows users to set the experimental process according to the analysis steps.</li>\r\n\t<li class=\"ed_txt\">Adding experimental steps is easy using the drop-down options, where users can define the microplate format, the number of readings, settling time, wavelength, and other experimental step settings.</li>\r\n\t<li class=\"ed_txt\">With the Multiassay function, one microwell plate can support various experiments and calculation parameters.</li>\r\n\t<li class=\"ed_txt\">The software has built-in enzyme kinetics formulas, and users can choose between Linear or Quadratic slope calculation methods and calculate the area under the curve they selected. The software also has built-in Lineweaver-Burk, Eadie-Hofstee, Hanes, and other drawing formulas for calculating Km and Vmax value&nbsp;formulas.</li>\r\n\t<li class=\"ed_txt\">One experimental method can be applied to several microplates without any changes.</li>\r\n\t<li class=\"ed_txt\">The software can read different combinations of filters and match different detection methods simultaneously.</li>\r\n\t<li class=\"ed_txt\">Users can set cycle parameters, reaction time differences, and specific conditions in the experimental cycle for enzyme kinetics.</li>\r\n\t<li class=\"ed_txt\">They can also set commands and reminders to be displayed during the experimental steps.</li>\r\n\t<li class=\"ed_txt\">After completing all measurements, the experimental data will be automatically saved in Excel format.</li>\r\n</ol>\r\n</div>","page3Title":"Manuals and Instructional Videos","page3":"<div class=\"ed_model17 clearfix ed_list\">\r\n<ul>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">SPARK control Software-Chinese Simple Operation Manual</span> </span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"/userfiles/ordch/files/20231016112417843.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Dashboard Software-Chinese Simple Operation Manual (pdf) (Open a new window)\"><img alt=\"Dashboard Software-Chinese Simple Operation Manual\" src=\"/userfiles/file/pdf.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">SPARK control -Z-position settings&nbsp;</span></span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"/userfiles/ordch/files/20240507100619611.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"SPARK_How to set Z position(Open a new window)\"><img alt=\"SPARK_How to set Z position\" src=\"/userfiles/file/pdf.png\" /> </a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\"><span style=\"vertical-align: inherit;\"><span style=\"vertical-align: inherit;\">Magellan Software - Chinese Simple Operation Manual</span> </span>\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"/userfiles/ordch/files/20231016112501601.pdf\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Magellan Software - Chinese Simple Operation Manual (pdf) (Open a new window)\"><img alt=\"Magellan Software - Chinese Simple Operation Manual\" src=\"/userfiles/file/pdf.png\" /></a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\">&quot;Absorbance Measurement&quot; (12:50)\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"https://youtu.be/Uh2cS7PvDDo\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Open New Windows\"><img alt=\"&quot;Absorbed Light Measurement&quot; ( Play 12:50 )\" src=\"/userfiles/file/link.png\" /></a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\">&quot;Fluorescence Measurement&quot; (17:09)\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"https://youtu.be/z5ilvoqfwOg\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Open New Windows\"><img alt=\"&quot;Fluorescence Reading&quot; ( Playback 17:09 )\" src=\"/userfiles/file/link.png\" /></a></li>\r\n\t</ul>\r\n\t</li>\r\n\t<li class=\"d-flex\">&quot;Luminescence reading and Kinetic&quot; (13:54)\r\n\t<ul class=\"d-flex\">\r\n\t\t<li><a href=\"https://youtu.be/-Kl7L3nl5og\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Open New Windows\"><img alt=\"&quot;Cold light reading and Kinetic&quot; ( Playback 13:54 )\" src=\"/userfiles/file/link.png\" /></a></li>\r\n\t</ul>\r\n\t</li>\r\n</ul>\r\n</div>","page4Title":"Related Links","page4":"<div class=\"ed_model01 clearfix\">\r\n<div class=\"ed_txt\"><a href=\"https://lifesciences.tecan.com/plate_readers/infinite_200_pro\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"TECAN(Open in new window)\"><img alt=\"TECANＮ\" src=\"/userfiles/ordch/images/20231016111223919.jpg\" /></a><br />\r\n<a href=\"https://www.tecan.com/scaling-3d-spheroid-and-organoid-cell-experiments\" rel=\"noreferrer noopener\" target=\"_blank\" title=\"Research Application Reference Materials(Open New Window)\">Research Application References</a></div>\r\n</div>","page5Title":null,"page5":null,"page6Title":null,"page6":null,"page7Title":null,"page7":null,"page8Title":null,"page8":null,"docs":[],"images":[{"fileurl":"https://www.nycu.edu.tw/ord/en/app/machine/image?module=machine&detailNo=1167366378080964608&init=Y","expFile":"TECAN SPARK"}],"videos":[],"audios":[],"resources":[{"relateURL":"https://ord.edu.tw/ord/en/app/artwebsite/view?module=artwebsite&id=2023&serno=da69be39-dc4e-48d6-9168-7c96b2dbdb6e","relateName":"Instrument List of YM Campus"},{"relateURL":"https://www.nycu.edu.tw/ord/en/app/machine/list?module=machine&id=2041","relateName":"Other Plate Readers"}]}