Link to Content Area

NYCU Office of Research and Development

Analyzers

  • Update Date:2025-02-20
  • Units:Instrumentation Resource Center
[Guangfu] Nanoelectronics and Optoelectronic probe station System (EL System)
Nano photoelectric measurement system
  • Nanoelectronics and Optoelectronic probe station System, EL System
  • Instrument Expert: Prof. Kuo, Hao-Chung
  • Instrument Operation Technician: Lee, Tzu-I
  • Instrument Location: R311, TKP Photonic Building
         
Instrument Specifications
Item Details
Power supply
  1. LDP-38-120V
  2. KEITHLEY 2420
  3. SpikeSafe 400 SMU
Spectrometer
  1. iHR550
  2. EE2051-025-NIR1
Light detector
  1. PD300R-UV
Integrating sphere
  1. 3P-LPM-060-SLentrance port size: 1.5 inch
  2. Si Detector (SDA-050-U-RTA-CX): with 800-1000nm @1nm calibration file;
    Max. power range: 0.1-20W laser with up to 160° divergent angle SMA connector for fiber
  • Year of Purchase: 2021
Important Specifications
  • Application: Nanoelectronics and photoelectric probe testing system
    1. The light absorption range of the spectrometer includes the blue light bandwidth to the ultraviolet light bandwidth.
    2. A light detection system that can receive small light signals and has a wide input current range (nA / µA – 10 A).
    3. The modes of the high-precision probe are divided into Stepping Mode and Scanning Mode, which can perform analytical displacement ability of (<50 nm / <1.5 nm), respectively.
Services
p-n Junction, L-I-V curve measurement

Opening Hours
  1. Monday, Tuesday, and Friday morning hours (9:00-12:00)
  2. Night and holiday hours: closed
System Opening Level
  1. General working hours: Level D
  2. Night and holiday hours: closed
Level Description
  • Level A: Open to students who need to use it. They can operate it on their own after training and assessment.
  • Level B: Each professor nominates one student for training, while the rest operate under those who have been trained. Professors with multiple students using the instrument can request an increase in the number of students receiving training.
  • Level C: The instrument administrator selects several students recommended by the professor to receive training. After passing the assessment, they can self-operate the instrument and be responsible for delegated operation service.
  • Level D: The laboratory's technical staff only accept delegated services and are unavailable for general use.
Charging standards
  Delegated operation Delegated operation
Units Academic unit Manufacturers and research units
On campus NT$400 /hour
Off-campus NT$600 /hour NT$1,200 /hour

Note: Academic units refer to colleges and universities.
Management and Usage Regulations:
  • Users inside and outside the school can use commissioned test strips to obtain the services of this instrument
Instrument operation appointment:
  • Please contact the instrument operation technician
Contact:
  • Instrument expert: Prof. Kuo, Hao-Chung
  • Instrument operation technician: Lee, Tzu-I
gotop