Analyzers
- Update Date:2025-02-20
- Units:Instrumentation Resource Center
[Guangfu] Nanoelectronics and Optoelectronic probe station System (EL System)

- Nanoelectronics and Optoelectronic probe station System, EL System
- Instrument Expert: Prof. Kuo, Hao-Chung
- Extension 56333
- Mailbox hckuo0206@nycu.edu.tw
- Instrument Operation Technician: Lee, Tzu-I
- Extension 56354
- Mailbox a0981467512@gmail.com
- Instrument Location: R311, TKP Photonic Building
Item | Details |
---|---|
Power supply |
|
Spectrometer |
|
Light detector |
|
Integrating sphere |
|
- Year of Purchase: 2021
Important Specifications
- Application: Nanoelectronics and photoelectric probe testing system
- The light absorption range of the spectrometer includes the blue light bandwidth to the ultraviolet light bandwidth.
- A light detection system that can receive small light signals and has a wide input current range (nA / µA – 10 A).
- The modes of the high-precision probe are divided into Stepping Mode and Scanning Mode, which can perform analytical displacement ability of (<50 nm / <1.5 nm), respectively.
Services
p-n Junction, L-I-V curve measurement
Opening Hours
p-n Junction, L-I-V curve measurement
Opening Hours
- Monday, Tuesday, and Friday morning hours (9:00-12:00)
- Night and holiday hours: closed
System Opening Level
- General working hours: Level D
- Night and holiday hours: closed
Level Description
- Level A: Open to students who need to use it. They can operate it on their own after training and assessment.
- Level B: Each professor nominates one student for training, while the rest operate under those who have been trained. Professors with multiple students using the instrument can request an increase in the number of students receiving training.
- Level C: The instrument administrator selects several students recommended by the professor to receive training. After passing the assessment, they can self-operate the instrument and be responsible for delegated operation service.
- Level D: The laboratory's technical staff only accept delegated services and are unavailable for general use.
Delegated operation | Delegated operation | |
---|---|---|
Units | Academic unit | Manufacturers and research units |
On campus | NT$400 /hour | — |
Off-campus | NT$600 /hour | NT$1,200 /hour |
Note: Academic units refer to colleges and universities.
Management and Usage Regulations:
- Users inside and outside the school can use commissioned test strips to obtain the services of this instrument
Instrument operation appointment:
- Please contact the instrument operation technician
Contact:
- Instrument expert: Prof. Kuo, Hao-Chung
- Telephone: 03-5712121 extension 56333
- Mailbox: hckuo0206@nycu.edu.tw
- Instrument operation technician: Lee, Tzu-I
- Telephone: 03-5712121 extension 56354
- Mailbox: a0981467512@gmail.com
Related Image(s):